Computer-Aided Design, 3-D-Printed Manufacturing, and Expert Validation of a High-fidelity Facial Flap Surgical Simulator.
Abstract
[IMPORTANCE] Facial flap procedures may be difficult for surgical trainees to conceptualize and challenging for supervising surgeons to allow entrustment early in training. Simulation outside of the operating room may accelerate and enhance the surgical education experience.
[OBJECTIVE] To design and manufacture a 3-dimensional (3-D)-printed, multilayer, anatomically accurate facial flap model for use in surgical education.
[DESIGN, SETTING, AND PARTICIPANTS] In this multicenter validation study, a 3-D-printed facial flap simulator was designed from a computed tomographic (CT) scan and manufactured for low-cost, high-fidelity simulation. Expert otolaryngology-head and neck surgeon feedback was acquired through surgical rehearsal and performance of 8 local facial flap procedures on the facial flap simulator by 7 otolaryngologists fellowship trained in facial plastic surgery.
[MAIN OUTCOMES AND MEASURES] Likert scale surveys were made based on evaluation criteria categorized into domains of realism, experience, and applicability of the simulator. Measures of central tendency, variability, and confidence intervals were generated to evaluate the outcomes.
[RESULTS] Seven expert otolaryngology-head and neck surgeons completed a Likert scale evaluation survey containing quantitative analysis of 6 questions on physical attributes, 12 questions on realism, 8 questions on experience, and 4 questions on the applicability of the simulator. All expert surgeons were additionally fellowship trained in facial plastic surgery with their mean years in practice being 11.9. Overall evaluation demonstrated valuable ability of the simulator for medical education with suggestions for future directions. Importantly, the simulator was rated on a scale of 1 (no value) to 4 (great value) as 3.86 as a training tool, 3.57 as a competency evaluation tool, and 3.43 as a rehearsal tool.
[CONCLUSIONS AND REVELANCE] Expert experience with the local facial flap simulator was rated highly for realism, experience, performance, and usefulness. With slight refinement, the model has strong potential for broad use in training in otolaryngology-head and neck surgery and facial plastic surgery.
[LEVEL OF EVIDENCE] NA.
[OBJECTIVE] To design and manufacture a 3-dimensional (3-D)-printed, multilayer, anatomically accurate facial flap model for use in surgical education.
[DESIGN, SETTING, AND PARTICIPANTS] In this multicenter validation study, a 3-D-printed facial flap simulator was designed from a computed tomographic (CT) scan and manufactured for low-cost, high-fidelity simulation. Expert otolaryngology-head and neck surgeon feedback was acquired through surgical rehearsal and performance of 8 local facial flap procedures on the facial flap simulator by 7 otolaryngologists fellowship trained in facial plastic surgery.
[MAIN OUTCOMES AND MEASURES] Likert scale surveys were made based on evaluation criteria categorized into domains of realism, experience, and applicability of the simulator. Measures of central tendency, variability, and confidence intervals were generated to evaluate the outcomes.
[RESULTS] Seven expert otolaryngology-head and neck surgeons completed a Likert scale evaluation survey containing quantitative analysis of 6 questions on physical attributes, 12 questions on realism, 8 questions on experience, and 4 questions on the applicability of the simulator. All expert surgeons were additionally fellowship trained in facial plastic surgery with their mean years in practice being 11.9. Overall evaluation demonstrated valuable ability of the simulator for medical education with suggestions for future directions. Importantly, the simulator was rated on a scale of 1 (no value) to 4 (great value) as 3.86 as a training tool, 3.57 as a competency evaluation tool, and 3.43 as a rehearsal tool.
[CONCLUSIONS AND REVELANCE] Expert experience with the local facial flap simulator was rated highly for realism, experience, performance, and usefulness. With slight refinement, the model has strong potential for broad use in training in otolaryngology-head and neck surgery and facial plastic surgery.
[LEVEL OF EVIDENCE] NA.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | flap
|
피판재건술 | dict | 7 | |
| 합병증 | facial flap
|
scispacy | 1 | ||
| 약물 | [IMPORTANCE] Facial flap
|
scispacy | 1 | ||
| 약물 | [OBJECTIVE]
|
scispacy | 1 | ||
| 약물 | [DESIGN
|
scispacy | 1 | ||
| 약물 | [MAIN OUTCOMES AND
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS AND
|
scispacy | 1 |
MeSH Terms
Computer-Aided Design; Face; Humans; Otolaryngology; Printing, Three-Dimensional; Simulation Training; Surgery, Plastic; Surgical Flaps
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- From Palliation After Angiosarcoma Resection to Totally Autologous Aesthetic Breast Reconstruction Combining Kiss Latissimus Dorsi Flap and Contralateral Breast Sharing Internal Mammary Artery Perforator Flap: A Case Report.
- Case report of a rare soft tissue tuberculosis in a patient undergoing lipoabdominoplasty.
- Otoplasty for prominent ear: A systematic review of surgical techniques.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Free flap reconstruction of a cast-related pressure ulcer in a pediatric patient with spinal muscular atrophy.