Breast Morphological Comparison Between Anatomic and Round Implant Augmentation: A Prospective Study.

Annals of plastic surgery 2023 Vol.90(1) p. 19-26

Liu Y, Zhang X, Luan J

관련 도메인

Abstract

[BACKGROUND] The choice of implant shape (anatomic or round) is one of the most critical issues for breast augmentation. Determining whether there are differences in the postoperative breast morphology of the 2 implants is pivotal for surgical planning. This issue has been controversial and lacking in evidence. The aim of this study was to provide reference for implant selection by comparing breast morphology after dual-plane augmentation with anatomic and round implants using 3-dimensional scanning technology.

[METHODS] Patients with implant volume less than 300 mL who underwent transaxillary dual-plane augmentation were included in this study and were grouped according to implant shape. Three-dimensional scans were performed preoperatively and 6 months postoperatively. Postoperative breast height (BH), breast width (BW), BH of upper pole (BHUP), BH of lower pole (BHLP), breast projection (BP), BP of upper pole (BPUP), and BP of lower pole (BPLP) were measured separately, resulting in corresponding ratios (BH/BW, BHUP/BHLP, BP/BH, BPUP/BPLP). Breast volume, and the volumes of each pole (breast volume of upper pole [BVUP], breast volume of lower pole [BVLP]) and its ratio (BVUP/BVLP) were calculated. Correlation and regression analysis on the influencing factors of breast volume were performed.

[RESULTS] Thirty patients with anatomic implants and 26 with round implants were enrolled in this study. The mean volumes of anatomic and round implants were 260.5 ± 26.7 and 267.9 ± 21.7 mL (P = 0.192). The ratios of BH/BW in the 2 groups were 1.39 ± 0.12 and 1.37 ± 0.19, respectively (P = 0.582). The BHUP/BHLP values of 2 groups were 1.35 ± 0.22 and 1.41 ± 0.25 (P = 0.160). Two sets of BPUP/BPLP were 0.68 ± 0.19 and 0.73 ± 0.17 (P = 0.133). The ratios of BP/BH in the 2 groups were 0.39 ± 0.08 and 0.39 ± 0.06 (P = 0.830). The BVUP/BVLP ratios for both groups were 0.75 ± 0.11 and 0.77 ± 0.12 (P = 0.287). There was a volume loss rate of 13.3% ± 3.9% and 13.9% ± 5% (P = 0.489). The postoperative volume showed a positive correlation with both the preoperative volume and the implant volume.

[CONCLUSIONS] For patients with breast dysplasia undergoing transaxillary dual-plane augmentation with anatomic or round implants less than 300 mL, the difference in postoperative breast morphology is not obvious. Using these 2 shapes of implants results in a similar degree of volume loss.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 breast 유방 dict 13
시술 breast augmentation 유방성형술 dict 1
해부 upper pole scispacy 1
합병증 breast height scispacy 1
약물 [BACKGROUND] scispacy 1
약물 [CONCLUSIONS] scispacy 1
질환 volume loss scispacy 1
질환 breast dysplasia C0016034
Breast Fibrocystic Disease
scispacy 1
질환 BPUP scispacy 1
기타 Patients scispacy 1
기타 BP/BH scispacy 1

MeSH Terms

Humans; Prospective Studies; Breast Implants; Breast Implantation; Breast; Mammaplasty

📑 인용 관계

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문