Hybrid breast augmentation: our surgical approach and formula for preoperative assessment of fat graft volume.

Gland surgery 2022 Vol.11(10) p. 1604-1614

Trignano E, Serra PL, Pili N, Trignano C, Rubino C

관련 도메인

Abstract

[BACKGROUND] Autogenous fat grafting (AFG) is a well-known procedure utilized in addition to breast augmentation (BA) to improve breast appearance. Plastic surgeons usually estimate the ideal AFG volume relying on their personal experience based on similar previous cases: inaccurate predictions could result in incorrect evaluation of donor sites and even needless fat transfer. The purpose of this paper is to describe and prove the validity of our surgical technique and provide a simple and easy-to-use mathematical formula to assess the adequate proportion, between the volume of the implants and of the AFG, in order to obtain a natural shape and a proper volume in BA.

[METHODS] One hundred and twenty-two patients (244 breasts) were subjected to primary/secondary hybrid BA (HBA). A formula was utilized to assess the volume of fat graft. Data about their age, body mass index (BMI), incision and implants were collected. Follow-up for analysis was fixed at less than 15 days, 1, 3, 6 and 12 months for analysis. Preoperative photographs were compared with postoperative at 12 months. Pre and postoperative Breast-Q were administered to every patient. A statistical analysis was performed comparing Breast-Q preoperative means with postoperative ones through -student test. We globally defined the patients as follows: "very dissatisfied" if total score 0-25; "somewhat dissatisfied", score 26-50; "somewhat satisfied", score 51-75; "very satisfied", score 76-100.

[RESULTS] All patients received Ergonomix-style Motiva Smooth/SilkSurface with low/high projection (range, 120-225 mL, mean 170 mL) and an average AFG volume of 600 mL (range, 480-720 mL). Breast-Q analysis showed a statistically significant difference between preoperative and postoperative modules; 122 (100%) patients were "very satisfied". Thirteen cases of complications presented in 12 patients (10.65%): 5 hypertrophic scarring (4.09%), 3 wound dehiscence (2.46%), 3 hematomas (2.46%), 1 seroma (0.82%), 1 fat necrosis (0.82%).

[CONCLUSIONS] Our surgical technique proves low complication rate and short recovery times. Our mathematical formula to calculate the AFG seems to be both predictive and a precise guide for surgical decision-making in planning the treatment of patients candidated for HBA. In fact, the analysis of Breast-Q questionnaires shows a high grade of satisfaction among patients. Further investigations should be performed in order to study a wider population and different type of implants.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 breast 유방 dict 7
시술 breast augmentation 유방성형술 dict 2
해부 fat graft scispacy 1
해부 fat scispacy 1
해부 hybrid BA scispacy 1
합병증 seroma 장액종 dict 1
합병증 necrosis 괴사 dict 1
합병증 wound dehiscence 상처열개 dict 1
합병증 wound scispacy 1
약물 [BACKGROUND] Autogenous fat grafting scispacy 1
약물 HBA → hybrid BA scispacy 1
질환 hypertrophic scarring C0162810
Cicatrix, Hypertrophic
scispacy 1
질환 hematomas C0018944
Hematoma
scispacy 1
질환 Hybrid breast scispacy 1
기타 AFG → Autogenous fat grafting scispacy 1

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문