The Value of Ultrasound in the Evaluation of the Integrity of Silicone Breast Implants.
Abstract
Breast implant surgery for cosmetic purposes is the most popular plastic surgery and it has been performed for over 100 years. Rupture of silicone gel-filled breast implants usually is asymptomatic and is one of the more dangerous complications due to free silicone migration. The aim of our study was to evaluate the diagnostic value of ultrasound (US) in the evaluation of the integrity of silicone breast implants and identify the main sign of intact and ruptured breast implants. In this retrospective study, the medical documentation of women who underwent breast implant surgery and US checkups at Tautrimas Aštrauskas Clinic in Kaunas, Lithuania, during 2015-2020 was analyzed. The patients were divided into two groups: patients with intact and ruptured breast implants. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) as well as the signs of implant integrity of US examination were evaluated. In this study, 76 women with bilateral breast implants ( = 152) were reviewed. On a US examination, ruptured implants were found in 41.1% ( = 61) of the cases; of them, 78.7% ( = 48) of the cases had ≥2 US signs of a ruptured implant, and in all these cases, implant rupture was confirmed at surgery. Overall, one US sign of a ruptured implant was found in 21.3% ( = 13) of the cases. Of them, inhomogeneous content in all cases ( = 3) was found in the intact implant group, and an abnormal implant shell was documented more often in the ruptured implant group, not intact one ( = 9, 90% vs. = 1, 10%). US had a diagnostic accuracy of 94.7%, sensitivity of 98.3%, specificity of 89.2%, PPV of 93.4%, and NPV of 97.1% in the evaluation of implant integrity. Our results show that US is a very reliable alternative in evaluating breast implant integrity and could be the investigation of choice for implant rupture, while MRI could be advocated only in inconclusive cases. Uneven implant shell was found to be the most important US sign of breast implant rupture. Based on the findings, we recommend performing US examination after breast augmentation surgery with silicone gel-filled implants annually.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 11 | |
| 합병증 | implant rupture
|
보형물 파열 | dict | 2 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 1 | |
| 합병증 | breast implant rupture
|
보형물 파열 | dict | 1 | |
| 합병증 | Breast implant
|
scispacy | 1 | ||
| 약물 | silicone
|
C0037114
silicones
|
scispacy | 1 | |
| 질환 | Silicone Breast
|
scispacy | 1 | ||
| 질환 | Rupture of silicone gel-filled breast implants
|
scispacy | 1 | ||
| 질환 | ruptured implant
|
scispacy | 1 | ||
| 질환 | rupture
|
C3203359
Rupture
|
scispacy | 1 | |
| 질환 | silicone gel-filled
|
scispacy | 1 | ||
| 질환 | Silicone Breast Implants
|
scispacy | 1 | ||
| 질환 | breast implant
|
scispacy | 1 | ||
| 질환 | Tautrimas
|
scispacy | 1 | ||
| 질환 | bilateral breast
|
scispacy | 1 | ||
| 기타 | women
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 |
MeSH Terms
Breast Implants; Female; Humans; Lithuania; Magnetic Resonance Imaging; Prosthesis Failure; Retrospective Studies; Silicone Gels
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.