Types of Errors Made During Breast Augmentation with Polyurethane Implants: A Systematic Review.
Abstract
[BACKGROUND] Implementation of polyurethane-covered (PU) implants into practice requires a reassessment of the experience and a learning curve period. Occasional publications describe a few difficulties in this regard. However, there are no publications covering the spectrum of errors. The absence of definite information and contradictory findings makes the learning curve longer leading to many unsatisfactory results.
[MATERIALS AND METHODS] The systematization is based on the 12 years of experience with over 1000 patients and previously published data. A literature review was conducted using PUBMED with the following keywords: polyurethane or foam or sponge and breast and implant. A total of 285 articles were found (last accessed 08/13/2019). All articles concerning polyurethane implants were studied along with any articles found describing the surgical techniques applied to them. Additional references found in the above-mentioned articles were also included in the study.
[RESULTS] All errors can be divided into planning errors, errors in pocket development and surface-dependent errors, for which the polyurethane surface is the main reason. Surface-dependent errors include the errors connected to positioning and biointegration. The possible causes of late seroma with PU implants are discussed.
[CONCLUSIONS] The polyurethane surface should not be considered textured in the clinical point of view. Previous experience with non-PU implants cannot be transferred to PU implants. The learning curve is unavoidable. The systematization of errors with PU implants facilitates a decision-making process during the primary and secondary surgery and lowers the risk of the unsatisfactory results.
[LEVEL OF EVIDENCE IV] This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine Ratings, please refer to Table of Contents or online Instructions to Authors www.springer.com/00266.
[MATERIALS AND METHODS] The systematization is based on the 12 years of experience with over 1000 patients and previously published data. A literature review was conducted using PUBMED with the following keywords: polyurethane or foam or sponge and breast and implant. A total of 285 articles were found (last accessed 08/13/2019). All articles concerning polyurethane implants were studied along with any articles found describing the surgical techniques applied to them. Additional references found in the above-mentioned articles were also included in the study.
[RESULTS] All errors can be divided into planning errors, errors in pocket development and surface-dependent errors, for which the polyurethane surface is the main reason. Surface-dependent errors include the errors connected to positioning and biointegration. The possible causes of late seroma with PU implants are discussed.
[CONCLUSIONS] The polyurethane surface should not be considered textured in the clinical point of view. Previous experience with non-PU implants cannot be transferred to PU implants. The learning curve is unavoidable. The systematization of errors with PU implants facilitates a decision-making process during the primary and secondary surgery and lowers the risk of the unsatisfactory results.
[LEVEL OF EVIDENCE IV] This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine Ratings, please refer to Table of Contents or online Instructions to Authors www.springer.com/00266.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 2 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 1 | |
| 해부 | surface-dependent
|
scispacy | 1 | ||
| 합병증 | seroma
|
장액종 | dict | 1 | |
| 약물 | non-PU
|
scispacy | 1 | ||
| 약물 | [BACKGROUND]
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS] The polyurethane surface
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 |
MeSH Terms
Breast Implantation; Breast Implants; Humans; Mammaplasty; Polyurethanes; Prosthesis Design
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.