Reoperation Rate After Primary Augmentation With Smooth, Textured, High Fill, Cohesive, Round Breast Implants (RANBI-I Study).
Abstract
[BACKGROUND] Reoperation after primary breast augmentation remains an important clinical issue.
[OBJECTIVE] The authors sought to evaluate incidence and causes of reoperation in patients who underwent primary augmentation.
[METHODS] This retrospective, noninterventional study conducted at 16 Canadian sites reviewed medical records and patient-completed questionnaires of women who underwent primary breast augmentation with smooth or textured Natrelle Inspira implants containing TruForm 1 or TruForm 2 gel. Patients were aged ≥22 years, received implants via inframammary fold incision, and returned for follow-up at 2 to 4 years.
[RESULTS] A total of 319 women received Inspira implants (smooth TruForm 2, n = 205; textured TruForm 2, n = 99; smooth or textured TruForm 1, n = 15). At follow-up, 30 women (9.4%) had undergone reoperation, including 19 (9.3%) in the smooth TruForm 2 subgroup and 9 (9.1%) in the textured TruForm 2 subgroup. The mean time to reoperation was 1.2 years; the risk rate for reoperation was 9.9% at 3 years. The most common reasons for reoperation were implant malposition (36.7%), capsular contracture (33.3%), and the patient's request for a change in implant size or style (20.0%). Most women were very or somewhat satisfied with the initial surgery (89.3% overall; 90.7% smooth TruForm 2; 86.9% textured TruForm 2). Thirty-four women (10.7%) reported adverse events, including 20 (9.8%) in the smooth TruForm 2 subgroup and 14 (14.1%) in the textured TruForm 2 subgroup.
[CONCLUSIONS] This analysis suggests that Natrelle Inspira TruForm 2 implants are safe when used in primary breast augmentation, resulting in low reoperation rates that are consistent with those for other breast implants.
[OBJECTIVE] The authors sought to evaluate incidence and causes of reoperation in patients who underwent primary augmentation.
[METHODS] This retrospective, noninterventional study conducted at 16 Canadian sites reviewed medical records and patient-completed questionnaires of women who underwent primary breast augmentation with smooth or textured Natrelle Inspira implants containing TruForm 1 or TruForm 2 gel. Patients were aged ≥22 years, received implants via inframammary fold incision, and returned for follow-up at 2 to 4 years.
[RESULTS] A total of 319 women received Inspira implants (smooth TruForm 2, n = 205; textured TruForm 2, n = 99; smooth or textured TruForm 1, n = 15). At follow-up, 30 women (9.4%) had undergone reoperation, including 19 (9.3%) in the smooth TruForm 2 subgroup and 9 (9.1%) in the textured TruForm 2 subgroup. The mean time to reoperation was 1.2 years; the risk rate for reoperation was 9.9% at 3 years. The most common reasons for reoperation were implant malposition (36.7%), capsular contracture (33.3%), and the patient's request for a change in implant size or style (20.0%). Most women were very or somewhat satisfied with the initial surgery (89.3% overall; 90.7% smooth TruForm 2; 86.9% textured TruForm 2). Thirty-four women (10.7%) reported adverse events, including 20 (9.8%) in the smooth TruForm 2 subgroup and 14 (14.1%) in the textured TruForm 2 subgroup.
[CONCLUSIONS] This analysis suggests that Natrelle Inspira TruForm 2 implants are safe when used in primary breast augmentation, resulting in low reoperation rates that are consistent with those for other breast implants.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 5 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 3 | |
| 해부 | smooth
|
scispacy | 1 | ||
| 해부 | inframammary
|
scispacy | 1 | ||
| 해부 | smooth TruForm 2
|
scispacy | 1 | ||
| 합병증 | capsular contracture
|
피막구축 | dict | 1 | |
| 약물 | RANBI-I
|
scispacy | 1 | ||
| 약물 | [BACKGROUND]
|
scispacy | 1 | ||
| 약물 | [OBJECTIVE]
|
scispacy | 1 | ||
| 약물 | [RESULTS] A
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS]
|
scispacy | 1 | ||
| 질환 | RANBI-I
|
scispacy | 1 | ||
| 질환 | primary breast augmentation
|
scispacy | 1 | ||
| 질환 | ≥22
|
scispacy | 1 | ||
| 질환 | implant malposition
|
C4552558
Implant malposition
|
scispacy | 1 | |
| 질환 | Smooth
|
scispacy | 1 | ||
| 질환 | Breast Implants
|
scispacy | 1 | ||
| 기타 | Fill
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 | ||
| 기타 | women
|
scispacy | 1 | ||
| 기타 | Inspira implants (
|
scispacy | 1 | ||
| 기타 | patient
|
scispacy | 1 |
MeSH Terms
Adult; Breast Implantation; Breast Implants; Canada; Female; Follow-Up Studies; Humans; Implant Capsular Contracture; Incidence; Middle Aged; Patient Satisfaction; Postoperative Complications; Prosthesis Design; Reoperation; Retrospective Studies; Surveys and Questionnaires; Young Adult
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.