Is Rotation a Concern with Anatomical Breast Implants? A Statistical Analysis of Factors Predisposing to Rotation.
Abstract
[BACKGROUND] Since their introduction in 1993, anatomical implants have provided a more natural appearance in breast augmentation, and many surgeons advocate their use and promote the good aesthetic results. However, the risk of implant rotation makes some of them reluctant to use these devices. The rotation rate varies among authors.
[METHODS] The authors present a 6.5-year series of 531 patients who underwent primary breast augmentation with macrotextured anatomical implants in a Swedish facility performed by one consultant surgeon (P.M.). The authors examined the rotation rate and the correlation with possible predisposing factors such as preoperative breast cup size, childbirth, and body mass index.
[RESULTS] A total of 20 implants (1.88 percent; 95 percent CI, 1.15 to 2.89 percent) in 19 patients (3.58 percent; 95 percent CI, 2.17 to 5.53 percent) were rotated. In one patient (0.22 percent), both implants rotated, whereas in the remaining patients, the rotation was unilateral. The authors were unable to establish a statistically significant correlation between implant rotation and previous childbirth or increased body mass index. However, there was a relation between rotation rate and preoperative breast cup size that showed an upward trend as the cup size increased from A to C.
[CONCLUSION] The authors believe that if the implant is correctly selected and the operation is performed meticulously with proper pocket dissection, the rotation rate is minimal and it should not be considered a disadvantage for the use of anatomical implants.
[CLINICAL QUESTION/LEVEL OF EVIDENCE] Risk, III.
[METHODS] The authors present a 6.5-year series of 531 patients who underwent primary breast augmentation with macrotextured anatomical implants in a Swedish facility performed by one consultant surgeon (P.M.). The authors examined the rotation rate and the correlation with possible predisposing factors such as preoperative breast cup size, childbirth, and body mass index.
[RESULTS] A total of 20 implants (1.88 percent; 95 percent CI, 1.15 to 2.89 percent) in 19 patients (3.58 percent; 95 percent CI, 2.17 to 5.53 percent) were rotated. In one patient (0.22 percent), both implants rotated, whereas in the remaining patients, the rotation was unilateral. The authors were unable to establish a statistically significant correlation between implant rotation and previous childbirth or increased body mass index. However, there was a relation between rotation rate and preoperative breast cup size that showed an upward trend as the cup size increased from A to C.
[CONCLUSION] The authors believe that if the implant is correctly selected and the operation is performed meticulously with proper pocket dissection, the rotation rate is minimal and it should not be considered a disadvantage for the use of anatomical implants.
[CLINICAL QUESTION/LEVEL OF EVIDENCE] Risk, III.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 5 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 2 | |
| 약물 | [BACKGROUND]
|
scispacy | 1 | ||
| 약물 | [RESULTS] A
|
scispacy | 1 | ||
| 약물 | [CONCLUSION]
|
scispacy | 1 | ||
| 질환 | primary breast augmentation
|
scispacy | 1 | ||
| 질환 | Breast Implants
|
scispacy | 1 | ||
| 질환 | breast cup
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 | ||
| 기타 | patient
|
scispacy | 1 |
MeSH Terms
Adult; Breast Implantation; Breast Implants; Chi-Square Distribution; Cohort Studies; Databases, Factual; Esthetics; Female; Follow-Up Studies; Humans; Middle Aged; Patient Satisfaction; Prosthesis Design; Prosthesis Failure; Reoperation; Retrospective Studies; Risk Assessment; Rotation; Sweden; Time Factors; Treatment Outcome
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.