Semiquantitative measurements of capsular contracture with elastography--first results in correlation to Baker Score.
Abstract
[BACKGROUND] To estimate the presence and severity of capsular contracture in patients after breast implants an objective measurement tool is necessary.
[PATIENTS AND METHODS] Eleven patients (range of age 37 to 53 years) who underwent cosmetic breast augmentation (seven patients with bilateral implants) or breast reconstruction by mammary asymmetry (four patients unilateral) with smooth silicone gel implants were included in this prospective study. In total seventeen implants were examined clinically and with the colour coded Ultrasound Elastography using a multifrequency probe (5-10 MHz Siemens Antares Premium VFX13-5). The grade of capsular contracture was assessed by two examiners with the palpation method and classified according to the Baker score. The Ultrasound Elastography was performed by two radiologists specialized in breast imaging and was correlated with the Baker score, colour coded ultrasound elastography and a high resolution ultrasound B-scan score (0-5).
[RESULTS] The clinical examination proved following distribution of the Baker degree: 6 breast implants with Baker grade I and Baker grade II, 3 breast implants with Baker grade III and two breast implants with Baker grade IV. There was a high correlation between the Baker score and the objective scoring measured by Ultrasound Elastography (kappa 0.83-0.89).
[CONCLUSION] The new technology of Ultrasound Elastography represents a useful tool to evaluate the compressibility of the peri-implant capsule, the implant and the surrounding tissue.
[PATIENTS AND METHODS] Eleven patients (range of age 37 to 53 years) who underwent cosmetic breast augmentation (seven patients with bilateral implants) or breast reconstruction by mammary asymmetry (four patients unilateral) with smooth silicone gel implants were included in this prospective study. In total seventeen implants were examined clinically and with the colour coded Ultrasound Elastography using a multifrequency probe (5-10 MHz Siemens Antares Premium VFX13-5). The grade of capsular contracture was assessed by two examiners with the palpation method and classified according to the Baker score. The Ultrasound Elastography was performed by two radiologists specialized in breast imaging and was correlated with the Baker score, colour coded ultrasound elastography and a high resolution ultrasound B-scan score (0-5).
[RESULTS] The clinical examination proved following distribution of the Baker degree: 6 breast implants with Baker grade I and Baker grade II, 3 breast implants with Baker grade III and two breast implants with Baker grade IV. There was a high correlation between the Baker score and the objective scoring measured by Ultrasound Elastography (kappa 0.83-0.89).
[CONCLUSION] The new technology of Ultrasound Elastography represents a useful tool to evaluate the compressibility of the peri-implant capsule, the implant and the surrounding tissue.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 7 | |
| 합병증 | capsular contracture
|
피막구축 | dict | 3 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 1 | |
| 해부 | smooth
|
scispacy | 1 | ||
| 해부 | tissue
|
scispacy | 1 | ||
| 해부 | mammary
|
유방 | dict | 1 | |
| 합병증 | asymmetry
|
비대칭 | dict | 1 | |
| 약물 | silicone
|
C0037114
silicones
|
scispacy | 1 | |
| 약물 | [BACKGROUND]
|
scispacy | 1 | ||
| 질환 | cosmetic breast augmentation
|
scispacy | 1 | ||
| 질환 | peri-implant capsule
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 | ||
| 기타 | bilateral implants
|
scispacy | 1 | ||
| 기타 | VFX13
|
scispacy | 1 | ||
| 기타 | Baker degree: 6 breast
|
scispacy | 1 | ||
| 기타 | Baker grade II, 3 breast
|
scispacy | 1 |
MeSH Terms
Adult; Breast Implants; Contracture; Elasticity Imaging Techniques; Female; Humans; Middle Aged
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.