[Digital evaluation of breast symmetry with 3D scanning technique].
Abstract
[OBJECTIVE] To establish a standard method for digital evaluation of breast symmetry with 3D scanning technique.
[METHODS] From January 2009 to July 2010, 167 patients received 3D scanning before breast augmentation. The coordinate system was established and the 3D reconstructed breast models were analyzed by software. The discrepancy of nipple level, the distance between nipple to midline, inferior mammary fold location, breast width, breast projection, breast volume and anterior chest wall projection were measured.
[RESULTS] The mean discrepancy of nipple level, the distance between nipple to midline, IMF level, breast width, breast projection and anterior chest wall projection were (4. 8 +/- 3.9) mm, (4.5 +/- 3.4) mm, (4.6 +/- 3.7) mm, (4.8 +/- 2.9) mm, (5.4 +/- 3.9) mm and (4.8 +/- 3.3) mm, respectively. The mean difference of breast volume was (51 +/- 44) ml. The incidence of significant asymmetry was 73% (122/167)in nipple position, 95% (159/167)in breast shape, 38% (63/167)in anterior chest wall projection.
[CONCLUSIONS] 3D scanning technique can provide an accurate 3D measurement of breast. A thorough and objective evaluation of breast symmetry can be achieved.
[METHODS] From January 2009 to July 2010, 167 patients received 3D scanning before breast augmentation. The coordinate system was established and the 3D reconstructed breast models were analyzed by software. The discrepancy of nipple level, the distance between nipple to midline, inferior mammary fold location, breast width, breast projection, breast volume and anterior chest wall projection were measured.
[RESULTS] The mean discrepancy of nipple level, the distance between nipple to midline, IMF level, breast width, breast projection and anterior chest wall projection were (4. 8 +/- 3.9) mm, (4.5 +/- 3.4) mm, (4.6 +/- 3.7) mm, (4.8 +/- 2.9) mm, (5.4 +/- 3.9) mm and (4.8 +/- 3.3) mm, respectively. The mean difference of breast volume was (51 +/- 44) ml. The incidence of significant asymmetry was 73% (122/167)in nipple position, 95% (159/167)in breast shape, 38% (63/167)in anterior chest wall projection.
[CONCLUSIONS] 3D scanning technique can provide an accurate 3D measurement of breast. A thorough and objective evaluation of breast symmetry can be achieved.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 13 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 1 | |
| 해부 | IMF
|
scispacy | 1 | ||
| 해부 | nipple
|
scispacy | 1 | ||
| 해부 | mammary
|
유방 | dict | 1 | |
| 합병증 | asymmetry
|
비대칭 | dict | 1 | |
| 약물 | [OBJECTIVE]
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS] 3D
|
scispacy | 1 | ||
| 질환 | nipple to midline, inferior mammary fold location
|
scispacy | 1 | ||
| 질환 | nipple to midline, IMF level, breast width
|
scispacy | 1 | ||
| 질환 | nipple
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 | ||
| 기타 | midline
|
scispacy | 1 | ||
| 기타 | anterior chest wall
|
scispacy | 1 |
MeSH Terms
Adult; Breast; Female; Humans; Imaging, Three-Dimensional; Mammaplasty; Middle Aged; Software; Young Adult
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.