Clinical accuracy and reproducibility of Portrait 3D Surgical Simulation Platform in breast augmentation.
Abstract
[BACKGROUND] Three-dimensional (3D) digital photography uses integrated image capture technology and rendering software to create 3D models. Volumetric measurements project simulated post-operative images prior to breast augmentation.
[OBJECTIVES] To evaluate the accuracy and reproducibility of breast volume measurements using the Portrait 3D Surgical Simulation Platform (Axis Three, Boston, Massachusetts).
[METHODS] Twenty-two patients underwent breast augmentation. 3D volumetric imaging analysis was performed by two independent observers preoperatively and at 6 weeks postoperatively. Simulated volumes were compared to actual implant volume using the Student's t test. Intra-observer reliability was evaluated by measuring internal consistency (Cronbach and 95% confidence interval [CI]) and test-retest reliability (intraclass correlation coefficient [ICC]) from the two observers' calculated volumes.
[RESULTS] Half (n = 11) of the patients received silicone implants and half saline; all were placed in the submuscular plane through an inframammary incision. No difference in volume estimation in preoperative or postoperative images (P = .49 and P = .14; and P = 1.0 and P = .37, in right and left breasts, respectively) was observed. The test-retest reliability between observers was excellent (ICC, 0.98; P < .001) and Cronbach's value (0.99; 95% CI 0.97-0.99; P < .001) demonstrated an excellent correlation. Regarding accuracy, difference in volume estimation between actual and simulated volumes varied between 0 to 106 mL (0 - 30%), with an absolute mean difference of 12.2% (42.5 mL).
[CONCLUSIONS] The Portrait 3D breast imaging system provides a highly reproducible 3D tool for measuring breast volume and simulating breast augmentation. Accuracy of the 3D models can vary up to 30% (mean 12.2%). This variability should be accounted for when using this technology to visually communicate with patients.
[OBJECTIVES] To evaluate the accuracy and reproducibility of breast volume measurements using the Portrait 3D Surgical Simulation Platform (Axis Three, Boston, Massachusetts).
[METHODS] Twenty-two patients underwent breast augmentation. 3D volumetric imaging analysis was performed by two independent observers preoperatively and at 6 weeks postoperatively. Simulated volumes were compared to actual implant volume using the Student's t test. Intra-observer reliability was evaluated by measuring internal consistency (Cronbach and 95% confidence interval [CI]) and test-retest reliability (intraclass correlation coefficient [ICC]) from the two observers' calculated volumes.
[RESULTS] Half (n = 11) of the patients received silicone implants and half saline; all were placed in the submuscular plane through an inframammary incision. No difference in volume estimation in preoperative or postoperative images (P = .49 and P = .14; and P = 1.0 and P = .37, in right and left breasts, respectively) was observed. The test-retest reliability between observers was excellent (ICC, 0.98; P < .001) and Cronbach's value (0.99; 95% CI 0.97-0.99; P < .001) demonstrated an excellent correlation. Regarding accuracy, difference in volume estimation between actual and simulated volumes varied between 0 to 106 mL (0 - 30%), with an absolute mean difference of 12.2% (42.5 mL).
[CONCLUSIONS] The Portrait 3D breast imaging system provides a highly reproducible 3D tool for measuring breast volume and simulating breast augmentation. Accuracy of the 3D models can vary up to 30% (mean 12.2%). This variability should be accounted for when using this technology to visually communicate with patients.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 7 | |
| 시술 | breast augmentation
|
유방성형술 | dict | 4 | |
| 해부 | inframammary
|
scispacy | 1 | ||
| 약물 | silicone
|
C0037114
silicones
|
scispacy | 1 | |
| 약물 | [BACKGROUND] Three-dimensional
|
scispacy | 1 | ||
| 약물 | [OBJECTIVES]
|
scispacy | 1 | ||
| 약물 | saline
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS]
|
scispacy | 1 | ||
| 기법 | submuscular
|
근막하 평면 | dict | 1 | |
| 질환 | Axis
|
C0004457
Axis vertebra
|
scispacy | 1 | |
| 기타 | patients
|
scispacy | 1 |
MeSH Terms
Breast; Female; Humans; Imaging, Three-Dimensional; Mammaplasty; Photography; Reproducibility of Results
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.