A versatile breast reduction technique: conical plicated central U shaped (COPCUs) mammaplasty.
Abstract
[BACKGROUND] There have been numerous studies on reduction mammaplasty and its modifications in the literature. The multitude of modifications of reduction mammaplasty indicates that the ideal technique has yet to be found. There are four reasons for seeking the ideal technique. One reason is to preserve functional features of the breast: breastfeeding and arousal. Other reasons are to achieve the real geometric and aesthetic shape of the breast with the least scar and are to minimize complications of prior surgical techniques without causing an additional complication. Last reason is the limitation of the techniques described before. To these aims, we developed a new versatile reduction mammaplasty technique, which we called conical plicated central U shaped (COPCUs) mammaplasty.
[METHODS] We performed central plication to achieve a juvenile look in the superior pole of the breast and to prevent postoperative pseudoptosis and used central U shaped flap to achieve maximum NAC safety and to preserve lactation and nipple sensation. The central U flap was 6 cm in width and the superior conical plication was performed with 2/0 PDS. Preoperative and postoperative standard measures of the breast including the superior pole fullness were compared.
[RESULTS] Forty six patients were operated with the above mentioned technique. All of the patients were satisfied with functional and aesthetic results and none of them had major complications. There were no changes in the nipple innervation. Six patients becoming pregnant after surgery did not experience any problems with lactation. None of the patients required scar revision.
[CONCLUSION] Our technique is a versatile, safe, reliable technique which creates the least scar, avoids previously described disadvantages, provides maximum preservation of functions, can be employed in all breasts regardless of their sizes.
[METHODS] We performed central plication to achieve a juvenile look in the superior pole of the breast and to prevent postoperative pseudoptosis and used central U shaped flap to achieve maximum NAC safety and to preserve lactation and nipple sensation. The central U flap was 6 cm in width and the superior conical plication was performed with 2/0 PDS. Preoperative and postoperative standard measures of the breast including the superior pole fullness were compared.
[RESULTS] Forty six patients were operated with the above mentioned technique. All of the patients were satisfied with functional and aesthetic results and none of them had major complications. There were no changes in the nipple innervation. Six patients becoming pregnant after surgery did not experience any problems with lactation. None of the patients required scar revision.
[CONCLUSION] Our technique is a versatile, safe, reliable technique which creates the least scar, avoids previously described disadvantages, provides maximum preservation of functions, can be employed in all breasts regardless of their sizes.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | mammaplasty
|
유방성형술 | dict | 5 | |
| 해부 | breast
|
유방 | dict | 5 | |
| 시술 | flap
|
피판재건술 | dict | 2 | |
| 시술 | breast reduction
|
유방성형술 | dict | 1 | |
| 시술 | scar revision
|
흉터교정술 | dict | 1 | |
| 해부 | nipple
|
scispacy | 1 | ||
| 해부 | central U flap was
|
scispacy | 1 | ||
| 해부 | breasts
|
scispacy | 1 | ||
| 해부 | nac
|
유방 | dict | 1 | |
| 합병증 | nipple innervation
|
scispacy | 1 | ||
| 합병증 | scar
|
scispacy | 1 | ||
| 질환 | postoperative pseudoptosis
|
scispacy | 1 | ||
| 질환 | breasts
|
C0006141
Breast
|
scispacy | 1 | |
| 질환 | scar
|
scispacy | 1 |
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.