[The value of sonography for the discovery of complications after the implantation of silicone gel prostheses for breast augmentation or reconstruction].

RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin 1997 Vol.166(3) p. 233-7

Lorenz R, Stark GB, Hedde JP

관련 도메인

Abstract

[PURPOSE] To determine sensitivity and specificity of real-time ultrasonography in detecting breast implant complications.

[MATERIAL AND METHODS] The results of preoperative ultrasonography of 121 silicone implants in 65 patients were compared with the results after operative implant removal.

[RESULTS] With a sensitivity of 89.25% and a specificity of 92.1%, complications such as gel bleeding (n = 43), rupture with leakage (n = 63), and implant dissolution (n = 4) become manifest. Capsule formation, fibrosis, siliconoma and calcifications were often underestimated in their extent. Negative ultrasonography findings were found in 10.7% (n = 13) with positive clinical findings.

[CONCLUSIONS] The combination of clinical and ultrasonography findings leads to the detection of implant complications.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 breast 유방 dict 2
시술 breast augmentation 유방성형술 dict 1
약물 silicone C0037114
silicones
scispacy 1
약물 [PURPOSE] scispacy 1
약물 [MATERIAL AND scispacy 1
약물 [CONCLUSIONS] scispacy 1
질환 breast implant C0178391
breast implant procedure
scispacy 1
질환 bleeding C0019080
Hemorrhage
scispacy 1
질환 rupture C3203359
Rupture
scispacy 1
질환 fibrosis C0016059
Fibrosis
scispacy 1
질환 calcifications C0006660
Physiologic calcification
scispacy 1
질환 Capsule scispacy 1
질환 siliconoma scispacy 1
기타 patients scispacy 1

MeSH Terms

Adult; Aged; Breast Implants; False Negative Reactions; Female; Gels; Humans; Mammaplasty; Middle Aged; Prosthesis Failure; Sensitivity and Specificity; Silicone Elastomers; Ultrasonography, Mammary

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문