Cannula Size Effect on Stromal Vascular Fraction Content of Fat Grafts.
Abstract
[BACKGROUND] Fat is an active and dynamic tissue composed of adipocytes supported by a structural framework known as the stromal vascular fraction (SVF). SVF is traditionally isolated by enzymatic processing, but new methods are being investigated to isolate it mechanically. Recent studies propose that fat harvested with larger cannulas has a higher survival rate, most likely due to a higher concentration of SVF.
[METHODS] Lipoaspirates were obtained from 10 patients who underwent elective liposuction using a 5-mm and a 1-mm cannula attached to a syringe using standard pressure. The fat was aspirated from the same area at adjacent sites. An estimated 5-mm fat particles were also cut down to 1-mm using a micronizer (Marina Medical). A 5-cm volume of each sample was compressed through a 0.5-mm opening strainer and rinsed with normal saline to extrude the oil. The resultant SVF left on the strainer was then measured in a 1-cm syringe.
[RESULTS] The volume extracted from a 5-mm cannula (mean, 0.23 cm; SD, 0.10) versus a 1-mm cannula (mean, 0.11 cm; SD, 0.06) was statistically significant ( = 0.009). An H&E-stained slide from the SVF was obtained for confirmation. Finally, 5-mm fat particles cut down to 1-mm particles using the micronizer resulted in an average volume of 0.20 cm, which was higher than the average volume harvested with a 1-mm cannula.
[CONCLUSIONS] Harvesting with a 5-mm cannula resulted in significantly more SVF than harvesting with a 1-mm cannula. Resizing fat particles harvested with a larger cannula down to 1-mm resulted in higher SVF than SVF obtained with a 1-mm cannula directly.
[METHODS] Lipoaspirates were obtained from 10 patients who underwent elective liposuction using a 5-mm and a 1-mm cannula attached to a syringe using standard pressure. The fat was aspirated from the same area at adjacent sites. An estimated 5-mm fat particles were also cut down to 1-mm using a micronizer (Marina Medical). A 5-cm volume of each sample was compressed through a 0.5-mm opening strainer and rinsed with normal saline to extrude the oil. The resultant SVF left on the strainer was then measured in a 1-cm syringe.
[RESULTS] The volume extracted from a 5-mm cannula (mean, 0.23 cm; SD, 0.10) versus a 1-mm cannula (mean, 0.11 cm; SD, 0.06) was statistically significant ( = 0.009). An H&E-stained slide from the SVF was obtained for confirmation. Finally, 5-mm fat particles cut down to 1-mm particles using the micronizer resulted in an average volume of 0.20 cm, which was higher than the average volume harvested with a 1-mm cannula.
[CONCLUSIONS] Harvesting with a 5-mm cannula resulted in significantly more SVF than harvesting with a 1-mm cannula. Resizing fat particles harvested with a larger cannula down to 1-mm resulted in higher SVF than SVF obtained with a 1-mm cannula directly.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | liposuction
|
지방흡입 | dict | 1 | |
| 해부 | Fat Grafts
|
scispacy | 1 | ||
| 해부 | tissue
|
scispacy | 1 | ||
| 해부 | adipocytes
|
scispacy | 1 | ||
| 해부 | SVF
→ stromal vascular fraction
|
scispacy | 1 | ||
| 해부 | fat
|
scispacy | 1 | ||
| 해부 | micronizer
|
scispacy | 1 | ||
| 해부 | oil
|
scispacy | 1 | ||
| 약물 | [BACKGROUND] Fat
|
scispacy | 1 | ||
| 약물 | saline
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS]
|
scispacy | 1 | ||
| 질환 | Stromal Vascular
|
scispacy | 1 | ||
| 기타 | stromal vascular
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 |
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Quantitative Assessment of Cannula Kinematics in Liposuction Surgical Procedures Using a Marker-Based Tracking System.
- Fat harvesting protocol for enhanced stem cell viability - pilot study.
- Scarless Infragluteal Fixation (SIF): Correction of Post-Liposuction Infragluteal Deformity.
- [Super microsurgical lymphaticovenular anastomosis for limb lymphedema: An outcome analysis based on clinical stage and indocyanine green pattern].
- Iatrogenic pneumothorax associated with surgeries at anatomically thoracic-adjacent and non-adjacent sites: case report and scoping review.