The use of Fibrin Sealants in Reducing Drain Output in Abdominoplasty: Is it Useful?
Abstract
[BACKGROUND] Abdominoplasty is a common surgical procedure in which excess abdominal skin and fat are reduced to improve body contouring. Fibrin sealant has been proposed to reduce postsurgical bleeding and exudation. In this study, we evaluated whether there was a significant statistical difference in surgical output between the use of fibrin glue and its nonuse in abdominoplasty surgery, specifically in reducing bleeding and exudation.
[MATERIAL AND METHODS] A retrospective chart review of 68 postbariatric abdominoplasty patients (58 females, 10 males) was performed. We divided the patients into Group A (30 cases, 44%), in which we used fibrin sealant, and Group B (38 cases, 56%), in which we did not use fibrin glue. We calculated the total amount of liquid in suction drainages until the day of their removal. Statistical analysis included the independent -test with a significance level of 0.05
[RESULTS] The average drainage output in Group A was 620.0 ± 375.0 mL, whereas in Group B, it was 500.0 ± 290.0 mL. Results indicate an insignificant correlation between the use of fibrin glue and the amount of liquid in the surgical drains ( = 1.52, = 0.13). The result is not significant at <.05 according to the independent -test.
[CONCLUSION] The use of fibrin sealant surely has a high value in all surgical branches to reduce postoperative complications, but in our study, we did not find any advantages in its use for reducing surgical drain output in abdominoplasty patients.
[MATERIAL AND METHODS] A retrospective chart review of 68 postbariatric abdominoplasty patients (58 females, 10 males) was performed. We divided the patients into Group A (30 cases, 44%), in which we used fibrin sealant, and Group B (38 cases, 56%), in which we did not use fibrin glue. We calculated the total amount of liquid in suction drainages until the day of their removal. Statistical analysis included the independent -test with a significance level of 0.05
[RESULTS] The average drainage output in Group A was 620.0 ± 375.0 mL, whereas in Group B, it was 500.0 ± 290.0 mL. Results indicate an insignificant correlation between the use of fibrin glue and the amount of liquid in the surgical drains ( = 1.52, = 0.13). The result is not significant at <.05 according to the independent -test.
[CONCLUSION] The use of fibrin sealant surely has a high value in all surgical branches to reduce postoperative complications, but in our study, we did not find any advantages in its use for reducing surgical drain output in abdominoplasty patients.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | abdominoplasty
|
복부성형술 | dict | 5 | |
| 해부 | skin
|
scispacy | 1 | ||
| 해부 | fat
|
scispacy | 1 | ||
| 해부 | body
|
scispacy | 1 | ||
| 약물 | 500.0 ±
|
scispacy | 1 | ||
| 약물 | [BACKGROUND] Abdominoplasty
|
scispacy | 1 | ||
| 약물 | [MATERIAL AND METHODS] A
|
scispacy | 1 | ||
| 질환 | bleeding
|
C0019080
Hemorrhage
|
scispacy | 1 | |
| 질환 | abdominoplasty patients
|
scispacy | 1 | ||
| 기타 | Fibrin
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 |
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Case report of a rare soft tissue tuberculosis in a patient undergoing lipoabdominoplasty.
- What is the potential role of the nonopioid suzetrigine in pain management?
- Ex Vivo and In Vivo Histological Evaluation of a 3-μm Wavelength, 40-μm Spot Size Fractional Laser System for Dermatology.
- Correspondence on "Lymphatic pathway remodeling in the supraumbilical region after abdominoplasty: A prospective cohort study".
- Sculpting Success-The TULUANHA: Modified TULUA Lipo-Abdominoplasty in Post-Bariatric Body Contouring.