The Architecture of Fat Grafting: What Lies beneath the Surface.
Abstract
[BACKGROUND] Fat grafting is a powerful procedure limited by unpredictable volume loss. Grafted tissue survives via plasmatic imbibition until neovascularization occurs; therefore, fat that is deposited more than 0.2 cm from capillaries will undergo central necrosis. This study aims to determine the architecture of fat deposits within the recipient bed following fat grafting.
[METHODS] Fat was harvested by liposuction and stained with methylene blue. Stained fat was grafted into 4 × 4 × 2-cm sections of pannus tissue at graft-to-recipient volume ratios ranging from 1:10 to 1:1. Each tissue block was sectioned for stained graft visualization. The diameter of each deposit and the percentage with a radius greater than 0.2 cm were recorded.
[RESULTS] Average tunnel diameter was 0.20 ± 0.01 cm at a graft-to-recipient ratio of 1:10, 0.25 ± 0.01 cm at 1:8, 0.26 ± 0.01 cm at 1:6, 0.31 ± 0.01 cm at 1:4, 0.40 ± 0.01 cm at 1:2, and 0.57 ± 0.02 cm at 1:1. All comparisons reached statistical significance (p ≤ 0.05) except 1:8 versus 1:6 (p = 0.96). The percentage of fat parcels with a radius greater than 0.2 cm was 3.0 percent at 1:10, 5.3 percent at 1:8, 9.5 percent at 1:6, 20.9 percent at 1:4, 42.0 percent at 1:2, and 68.3 percent at 1:1. All percentage comparisons were significant except 1:10 versus 1:8 (p = 0.15).
[CONCLUSION] As the total volume transferred increases, grafted deposits coalesce to form larger globules, particularly at ratios beyond 1:4, likely contributing to central necrosis and subsequent volume loss.
[CLINICAL QUESTION/LEVEL OF EVIDENCE] Therapeutic, V.
[METHODS] Fat was harvested by liposuction and stained with methylene blue. Stained fat was grafted into 4 × 4 × 2-cm sections of pannus tissue at graft-to-recipient volume ratios ranging from 1:10 to 1:1. Each tissue block was sectioned for stained graft visualization. The diameter of each deposit and the percentage with a radius greater than 0.2 cm were recorded.
[RESULTS] Average tunnel diameter was 0.20 ± 0.01 cm at a graft-to-recipient ratio of 1:10, 0.25 ± 0.01 cm at 1:8, 0.26 ± 0.01 cm at 1:6, 0.31 ± 0.01 cm at 1:4, 0.40 ± 0.01 cm at 1:2, and 0.57 ± 0.02 cm at 1:1. All comparisons reached statistical significance (p ≤ 0.05) except 1:8 versus 1:6 (p = 0.96). The percentage of fat parcels with a radius greater than 0.2 cm was 3.0 percent at 1:10, 5.3 percent at 1:8, 9.5 percent at 1:6, 20.9 percent at 1:4, 42.0 percent at 1:2, and 68.3 percent at 1:1. All percentage comparisons were significant except 1:10 versus 1:8 (p = 0.15).
[CONCLUSION] As the total volume transferred increases, grafted deposits coalesce to form larger globules, particularly at ratios beyond 1:4, likely contributing to central necrosis and subsequent volume loss.
[CLINICAL QUESTION/LEVEL OF EVIDENCE] Therapeutic, V.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 합병증 | necrosis
|
괴사 | dict | 2 | |
| 시술 | liposuction
|
지방흡입 | dict | 1 | |
| 해부 | Fat
|
scispacy | 1 | ||
| 해부 | Surface
|
scispacy | 1 | ||
| 해부 | tissue
|
scispacy | 1 | ||
| 해부 | capillaries
|
scispacy | 1 | ||
| 해부 | pannus tissue
|
scispacy | 1 | ||
| 해부 | graft
|
scispacy | 1 | ||
| 약물 | methylene blue
|
C0025746
methylene blue
|
scispacy | 1 | |
| 약물 | [BACKGROUND] Fat grafting
|
scispacy | 1 | ||
| 약물 | methylene
|
scispacy | 1 | ||
| 질환 | volume loss
|
scispacy | 1 | ||
| 질환 | pannus
|
C0155094
Corneal pannus
|
scispacy | 1 | |
| 질환 | 2-cm sections
|
scispacy | 1 |
MeSH Terms
Adipose Tissue; Female; Graft Rejection; Graft Survival; Humans; Lipectomy; Male; Methylene Blue; Prognosis; Plastic Surgery Procedures; Risk Assessment; Surgery, Plastic; Tissue Transplantation; Tissue and Organ Harvesting; Transplantation, Autologous
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Case report of a rare soft tissue tuberculosis in a patient undergoing lipoabdominoplasty.
- Pedicled extensor digitorum brevis flap for the distal third lower limb reconstruction: A review of the literature.
- Quantitative Assessment of Cannula Kinematics in Liposuction Surgical Procedures Using a Marker-Based Tracking System.
- Fat harvesting protocol for enhanced stem cell viability - pilot study.
- Scarless Infragluteal Fixation (SIF): Correction of Post-Liposuction Infragluteal Deformity.