A comparison of the efficacy of autologous fibrin glue/platelet-poor plasma versus suction drainage in preventing hematoma and seroma in rhytidectomy: A randomized, double-blind, controlled study.
Abstract
[BACKGROUND] One of the most feared complications of rhytidectomy is the formation of hematoma and seroma, which may harm patients' health and compromise the surgical outcome.
[OBJECTIVE] To compare the efficacy of autologous fibrin glue/platelet-poor plasma versus suction drainage in preventing surgical complications such as hematoma and seroma following rhytidectomy procedures.
[METHODS] A prospective, randomized, double-blind, controlled study was conducted to compare the efficacy of the two interventions. Seventy-two patients were selected and divided into two groups of 36 (autologous fibrin glue versus suction drainage). Forty-eight hours after the procedures, all patients underwent ultrasound examination, always by the same radiologist, to measure the volume of exudate under the facial skin flaps.
[RESULTS] The mean total volume of exudate was 3.21 mL in the suction drainage group and 1.02 mL in the fibrin glue group, with effect size of 68.1% and confidence interval of 55.3 to 77.2 (P < 0.001).
[CONCLUSIONS] Results significantly favor the use of fibrin glue and show that it was 68.1% more effective than suction drainage in preventing hematoma or seroma in rhytidectomy procedures.
[OBJECTIVE] To compare the efficacy of autologous fibrin glue/platelet-poor plasma versus suction drainage in preventing surgical complications such as hematoma and seroma following rhytidectomy procedures.
[METHODS] A prospective, randomized, double-blind, controlled study was conducted to compare the efficacy of the two interventions. Seventy-two patients were selected and divided into two groups of 36 (autologous fibrin glue versus suction drainage). Forty-eight hours after the procedures, all patients underwent ultrasound examination, always by the same radiologist, to measure the volume of exudate under the facial skin flaps.
[RESULTS] The mean total volume of exudate was 3.21 mL in the suction drainage group and 1.02 mL in the fibrin glue group, with effect size of 68.1% and confidence interval of 55.3 to 77.2 (P < 0.001).
[CONCLUSIONS] Results significantly favor the use of fibrin glue and show that it was 68.1% more effective than suction drainage in preventing hematoma or seroma in rhytidectomy procedures.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | rhytidectomy
|
안면거상술 | dict | 4 | |
| 합병증 | hematoma
|
혈종 | dict | 4 | |
| 합병증 | seroma
|
장액종 | dict | 4 | |
| 해부 | exudate
|
scispacy | 1 | ||
| 약물 | [BACKGROUND] One
|
scispacy | 1 | ||
| 약물 | [OBJECTIVE]
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS]
|
scispacy | 1 | ||
| 기타 | fibrin
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 | ||
| 기타 | skin flaps
|
scispacy | 1 |
MeSH Terms
Adult; Aged; Double-Blind Method; Drainage; Female; Fibrin Tissue Adhesive; Hematoma; Humans; Middle Aged; Plasma; Postoperative Complications; Prospective Studies; Rhytidoplasty; Seroma; Suction
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Implications of Dermatologic Disorders in Facial Cosmetic Surgery: A Systematic Review.
- Clinical safety of a low-modification hyaluronic acid filler (MoD 2%) for facial rejuvenation.
- Otoplasty for prominent ear: A systematic review of surgical techniques.
- Combined minimally invasive lymphatic microsurgery and aligned nanofibrillar collagen scaffold for refractory post-traumatic eyelid lymphedema: A case report.
- Tranexamic Acid in Reconstructive Microsurgery: A Systematic Review and Meta-Analysis.