Custom-Made Implant Fabrication for Chin Augmentation Using Piled-Up Expanded Polytetrafluoroethylene Sheets: An Innovative Surgical Technique and Literature Review.

Aesthetic plastic surgery 2024 Vol.48(11) p. 2018-2024

Guo JS, Ng KLB, Lee SS, Lai YW, Wu YC

관련 도메인

Abstract

[BACKGROUND] Alloplastic chin augmentation is the most common esthetic surgical treatment to reshape the chin. However, factory-made chin implants are typically standardized rather than custom-made and have potential to cause complications. Although the fabrication of custom-made implants by using computer-assisted planning and 3D-printing technology has become widespread, the process has several disadvantages, including long preoperative prosthesis preparation times, high costs, and unsuitability for patients with asymmetric chins or those who undergo combined mandibuloplasty before implant placement. The present study developed an innovative chin augmentation technique involving stacked expanded polytetrafluoroethylene (e-PTFE) sheets that is suitable for most patients and has minimal side effects.

[MATERIALS AND METHODS] A retrospective review of a single surgeon's experience was performed over a 2 year period for patients who underwent a procedure involving piled-up e-PTFE sheets for alloplastic chin augmentation. This study analyzed the outcomes, complications (temporary nerve numbness, wound infection, hematoma formation, and implant displacement), and patient satisfaction during follow-up.

[RESULTS] Between January 2018 and December 2020, 38 patients underwent the procedure involving piled-up e-PTFE sheets for alloplastic chin augmentation. Six patients (15.8%) experienced nerve-related temporary numbness, and one (2.6%) experienced wound infection. None had developed major complications such as implant displacement or wound infection at follow-up. Moreover, the patients demonstrated a high level of satisfaction with the surgical results.

[CONCLUSION] Piled-up e-PTFE sheets can be used to produce custom-fit porous polyethylene chin implants that result in minimal complications and a very high satisfaction rate.

[LEVEL OF EVIDENCE IV] This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 chin augmentation 턱끝성형술 dict 5
합병증 wound infection 감염 dict 3
재료 expanded polytetrafluoroethylene 고어텍스 dict 2
합병증 hematoma 혈종 dict 1
합병증 asymmetric 비대칭 dict 1
합병증 chin scispacy 1
합병증 wound scispacy 1
약물 [BACKGROUND] Alloplastic chin scispacy 1
질환 temporary nerve numbness scispacy 1
질환 infection C0009450
Communicable Diseases
scispacy 1
질환 numbness C0020580
Hypesthesia
scispacy 1
기타 Custom-Made scispacy 1
기타 patients scispacy 1
기타 patient scispacy 1
기타 nerve-related scispacy 1
기타 e-PTFE → expanded polytetrafluoroethylene scispacy 1

MeSH Terms

Humans; Polytetrafluoroethylene; Retrospective Studies; Female; Adult; Male; Chin; Prosthesis Design; Middle Aged; Esthetics; Patient Satisfaction; Prostheses and Implants; Young Adult; Treatment Outcome

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문