Validation of the OrthoGnathicAnalyser 2.0-3D accuracy assessment tool for bimaxillary surgery and genioplasty.

PloS one 2021 Vol.16(1) p. e0246196

Baan F, Sabelis JF, Schreurs R, van de Steeg G, Xi T, van Riet TCT, Becking AG, Maal TJJ

관련 도메인

Abstract

Orthognathic surgery is a widely performed procedure to correct dentofacial deformities. Virtual treatment planning is an important preparation step. One advantage of the use of virtual treatment planning is the possibility to assess the accuracy of orthognathic surgery. In this study, a tool (OrthoGnathicAnalyser 2.0), which allows for quantification of the accuracy of orthognathic surgery, is presented and validated. In the OrthoGnathicAnalyser 2.0 the accuracy of the osseous chin can now be assessed which was not possible in the earlier version of the OrthoGnathicAnalyser. 30 patients who underwent bimaxillary surgery in combination with a genioplasty were selected from three different centers in the Netherlands. A pre-operative (CB)CT scan, virtual treatment planning and postoperative (CB)CT scan were required for assessing the accuracy of bimaxillary surgery. The preoperative and postoperative (CB)CT scans were aligned using voxel-based matching. Furthermore, voxel-based matching was used to align the pre-operative maxilla, mandible and rami towards their postoperative position whereas surface-based matching was used for aligning the pre-operative chin towards the postoperative position. The alignment resulted in a transformation matrix which contained the achieved translations and rotations. The achieved translations and rotations can be compared to planning values of the virtual treatment plan. To study the reproducibility, two independent observers processed all 30 patients to assess the inter-observer variability. One observer processed the patients twice to assess the intra-observer variability. Both the intra- and inter-observer variability showed high ICC values (> 0.92) and low measurement variations (< 0.673±0.684mm and < 0.654±0.824°). The results of this study show that the OrthoGnathicAnalyser 2.0 has an excellent reproducibility for quantification of skeletal movements between two (CB)CT scans.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 orthognathic surgery 안면윤곽술 dict 3
시술 genioplasty 턱끝성형술 dict 2
해부 rami scispacy 1
해부 matrix scispacy 1
해부 skeletal scispacy 1
해부 mandible 하악골 dict 1
해부 maxilla 상악골 dict 1
합병증 osseous chin scispacy 1
질환 dentofacial deformities C3494419
Dentofacial Deformities
scispacy 1
기타 patients scispacy 1

MeSH Terms

Adult; Cone-Beam Computed Tomography; Female; Genioplasty; Humans; Imaging, Three-Dimensional; Male; Orthognathic Surgery; Patient Care Planning

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문