Blinking Parameters Do Not Normalize After Botulinum Toxin Therapy in Blepharospasm and Hemifacial Spasm Patients.

Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society 2023 Vol.43(4) p. 563-568

Gameiro GR, Osaki MH, Yabumoto C, Osaki T, Garcia DM, Belfort R, Cruz AAV, Osaki TH

관련 도메인

Abstract

[BACKGROUND] Little is known regarding changes induced by botulinum toxin injections on blinking parameters in blepharospasm (BSP) and hemifacial spasm (HFS) patients. The purpose of this study was to investigate objective changes induced by botulinum toxin (BoNT) injections on blinking parameters in BSP and HFS patients.

[METHODS] Thirty-seven patients with BSP and HFS were evaluated before and 30 days after receiving onabotulinumtoxinA injections. Twelve age-matched control subjects were also assessed. Pretreatment and post-treatment parameters were assessed and compared with normal controls. A high-speed camera and microlight-emitting diodes were used to register the blinking in patients and control groups. Outcomes were blinking frequency, amplitude, and maximum velocity of eyelid closure.

[RESULTS] BoNT injections led to a significant reduction in all parameters, compared with baseline, in BSP and on the affected side in HFS, respectively: 22% ( P < 0.001) and 20% ( P = 0.015) in amplitude; 21% ( P = 0.04) and 39% in frequency ( P = 0.002); and 41% ( P < 0.001) and 26% ( P = 0.005) in maximum closing velocity. Blinking amplitude ( P = 0.017 and P = 0.019) and velocity ( P < 0.001 for both groups) were significantly lower at 30 days on BSP and on the affected HFS side, when compared with controls. BSP and HFS patients presented a significantly lower velocity of eyelid closure, even before BoNT, compared with controls ( P = 0.004. and P < 0.001, respectively).

[CONCLUSIONS] Although blinking frequency became close to normal, amplitude and velocity after BoNT applications were significantly lower in BSP and on the affected side of HFS patients when compared with age-matched normal controls, demonstrating that blinking parameters do not normalize after treatment. The velocity of eyelid closure was shown to be significantly lower, even before BoNT treatment, when compared with control subjects.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 botulinum toxin 보툴리눔독소 주사 dict 3
해부 eyelid 눈꺼풀 dict 3
약물 BoNT → botulinum toxin C0006055
Botulinum Toxins
scispacy 1
약물 [BACKGROUND] scispacy 1
약물 onabotulinumtoxinA scispacy 1
약물 [RESULTS] BoNT scispacy 1
약물 [CONCLUSIONS] scispacy 1
질환 Blepharospasm C0005747
Blepharospasm
scispacy 1
질환 Hemifacial Spasm C0278152
Hemifacial Spasm
scispacy 1
질환 HFS → hemifacial spasm C0278152
Hemifacial Spasm
scispacy 1
기타 Patients scispacy 1
기타 BSP → blepharospasm scispacy 1
기타 BoNT → botulinum toxin scispacy 1

MeSH Terms

Humans; Blepharospasm; Blinking; Hemifacial Spasm; Botulinum Toxins, Type A; Blepharoplasty; Neuromuscular Agents

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문