Reliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients.
Abstract
[BACKGROUND] To explore the feasibility of corrected slack angle acquired from two-dimensional shear wave elastography (2D-SWE) for quantitating the spasticity of medial gastrocnemius (MG) in stroke patients.
[METHODS] Consecutive stroke patients with spastic MG and matched healthy controls were recruited. Intra- and interobserver reliability of 2D-SWE measurement were evaluated, and the correlation between corrected slack angle and modified Ashworth scale (MAS) score was examined. The corrected slack angle before and after botulinum toxin A (BoNT-A) injection was compared and its diagnostic performance in classifying the severity of spasticity were assessed with receiver operating characteristic (ROC) curve analysis.
[RESULTS] The intra- (0.791 95% CI 0.432-0.932) and interobserver (0.751 95% CI 0.382-0.916) reliability of slack angle acquired with 2D-SWE were good. Significant correlation was found between corrected slack angle and MAS score (R = - 0.849, p < 0.001). The corrected slack angle increased after BoNT-A injection. The cutoff value of MAS ≥ 3 had the highest sensitivity (100%) and specificity (93.33%). The positive predictive value (PPV) for classification of MAS ≥ 1+ and the negative predictive value (NPV) for classification of MAS ≥ 3 were greater than 90%.
[CONCLUSION] 2D-SWE was a reliable method to quantitate the post-stroke spasticity. The corrected slack angle had advantage in classifying the severity of spasticity, especially in early identification of mild spasticity and confirmation of severe spasticity.
[METHODS] Consecutive stroke patients with spastic MG and matched healthy controls were recruited. Intra- and interobserver reliability of 2D-SWE measurement were evaluated, and the correlation between corrected slack angle and modified Ashworth scale (MAS) score was examined. The corrected slack angle before and after botulinum toxin A (BoNT-A) injection was compared and its diagnostic performance in classifying the severity of spasticity were assessed with receiver operating characteristic (ROC) curve analysis.
[RESULTS] The intra- (0.791 95% CI 0.432-0.932) and interobserver (0.751 95% CI 0.382-0.916) reliability of slack angle acquired with 2D-SWE were good. Significant correlation was found between corrected slack angle and MAS score (R = - 0.849, p < 0.001). The corrected slack angle increased after BoNT-A injection. The cutoff value of MAS ≥ 3 had the highest sensitivity (100%) and specificity (93.33%). The positive predictive value (PPV) for classification of MAS ≥ 1+ and the negative predictive value (NPV) for classification of MAS ≥ 3 were greater than 90%.
[CONCLUSION] 2D-SWE was a reliable method to quantitate the post-stroke spasticity. The corrected slack angle had advantage in classifying the severity of spasticity, especially in early identification of mild spasticity and confirmation of severe spasticity.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | botulinum toxin
|
보툴리눔독소 주사 | dict | 1 |
MeSH Terms
Elasticity Imaging Techniques; Humans; Muscle Spasticity; Muscle, Skeletal; ROC Curve; Reproducibility of Results
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Local therapeutic strategies for neurocutaneous dysesthesia: from capsaicin to cannabinoids.
- Comparative efficacy of intralesional therapies for keloid scars: a network meta-analysis.
- Adverse neurological events following botulinum toxin type A: A case series of post-injection seizures and paralysis.
- Decreased utilization of component separation techniques over time in complex abdominal wall reconstruction following introduction of preoperative botulinum toxin A.
- Current Perspectives on Pectoralis Minor Syndrome: A Narrative Review.