Comparing Electrical Stimulation With and Without Ultrasound Guidance for Phenol Neurolysis to the Musculocutaneous Nerve.
Abstract
[BACKGROUND] Ultrasound guidance is increasingly being used for neurolytic procedures that have traditionally been done with electrical stimulation (e-stim) guidance alone. Ultrasound visualization with e-stim-guided neurolysis can potentially allow adjustments in injection protocols that will reduce the volume of neurolytic agent needed to achieve clinical improvement.
[OBJECTIVE] This study compared e-stim only to e-stim with ultrasound guidance in phenol neurolysis of the musculocutaneous nerve (MCN) for elbow flexor spasticity. We also evaluated the ultrasound appearance of the MCN in this population.
[DESIGN] Retrospective review.
[SETTING] University hospital outpatient clinic.
[PARTICIPANTS] Adults (N = 167) receiving phenol neurolysis to the MCN for treatment of elbow flexor spasticity between 1997 and 2014 and adult control subjects.
[METHODS] For each phenol injection of the MCN, the method of guidance, volume of phenol injected, technical success, improved range of motion at the elbow postinjection, adverse effects, reason for termination of injections, and details of concomitant botulinum toxin injection were recorded. The ultrasound appearance of the MCN, including nerve cross-sectional area and shape, were recorded and compared between groups.
[MAIN OUTCOME MEASURES] The volume of phenol injected and MCN cross-sectional area and shape as demonstrated by ultrasound.
[RESULTS] The addition of ultrasound to e-stim-guided phenol neurolysis was associated with lower doses of phenol when compared to e-stim guidance alone (2.31 mL versus 3.69 mL, P < .001). With subsequent injections, the dose of phenol increased with e-stim guidance (P < .001), but not with e-stim and ultrasound guidance (P = .95). Both methods of guidance had high technical success, improved ROM at elbow postinjection, and low rates of adverse events. In comparing the ultrasound appearance of the MCN in patients with spasticity to that of normal controls, there was no difference in the cross-sectional area of the nerve, but there was more variability in shape.
[CONCLUSIONS] Combined e-stim and ultrasound guidance during phenol neurolysis to the MCN allows a smaller volume of phenol to be used for equal effect, both at initial and repeat injection. The MCN shape was more variable in individuals with spasticity; this should be recognized so as to successfully locate the nerve to perform neurolysis.
[LEVEL OF EVIDENCE] IV.
[OBJECTIVE] This study compared e-stim only to e-stim with ultrasound guidance in phenol neurolysis of the musculocutaneous nerve (MCN) for elbow flexor spasticity. We also evaluated the ultrasound appearance of the MCN in this population.
[DESIGN] Retrospective review.
[SETTING] University hospital outpatient clinic.
[PARTICIPANTS] Adults (N = 167) receiving phenol neurolysis to the MCN for treatment of elbow flexor spasticity between 1997 and 2014 and adult control subjects.
[METHODS] For each phenol injection of the MCN, the method of guidance, volume of phenol injected, technical success, improved range of motion at the elbow postinjection, adverse effects, reason for termination of injections, and details of concomitant botulinum toxin injection were recorded. The ultrasound appearance of the MCN, including nerve cross-sectional area and shape, were recorded and compared between groups.
[MAIN OUTCOME MEASURES] The volume of phenol injected and MCN cross-sectional area and shape as demonstrated by ultrasound.
[RESULTS] The addition of ultrasound to e-stim-guided phenol neurolysis was associated with lower doses of phenol when compared to e-stim guidance alone (2.31 mL versus 3.69 mL, P < .001). With subsequent injections, the dose of phenol increased with e-stim guidance (P < .001), but not with e-stim and ultrasound guidance (P = .95). Both methods of guidance had high technical success, improved ROM at elbow postinjection, and low rates of adverse events. In comparing the ultrasound appearance of the MCN in patients with spasticity to that of normal controls, there was no difference in the cross-sectional area of the nerve, but there was more variability in shape.
[CONCLUSIONS] Combined e-stim and ultrasound guidance during phenol neurolysis to the MCN allows a smaller volume of phenol to be used for equal effect, both at initial and repeat injection. The MCN shape was more variable in individuals with spasticity; this should be recognized so as to successfully locate the nerve to perform neurolysis.
[LEVEL OF EVIDENCE] IV.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | botulinum toxin
|
보툴리눔독소 주사 | dict | 1 |
MeSH Terms
Electric Stimulation; Female; Follow-Up Studies; Humans; Male; Middle Aged; Muscle Spasticity; Musculocutaneous Nerve; Nerve Block; Phenol; Retrospective Studies; Sclerosing Solutions; Treatment Outcome; Ultrasonography
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Local therapeutic strategies for neurocutaneous dysesthesia: from capsaicin to cannabinoids.
- Comparative efficacy of intralesional therapies for keloid scars: a network meta-analysis.
- Adverse neurological events following botulinum toxin type A: A case series of post-injection seizures and paralysis.
- Decreased utilization of component separation techniques over time in complex abdominal wall reconstruction following introduction of preoperative botulinum toxin A.
- Current Perspectives on Pectoralis Minor Syndrome: A Narrative Review.