An interrater and intrarater reliability study of 3 photographic scales for the classification of perioral aesthetic features.
Abstract
[BACKGROUND] Validated aesthetic rating scales for the perioral area provide objective evaluations for clinical trials and practice.
[OBJECTIVE] To confirm the reliability of 3 scales for evaluating dermal filler and neurotoxin treatments of the perioral area.
[MATERIALS AND METHODS] Three lip-specific photographic scales were developed from standardized 2-dimensional images to evaluate Perioral Lines at Rest (POL), Oral Commissures (OCS), and Perioral Lines at Maximum Contraction (POLM) severity scales. Each 4-grade scale (none to severe) had 3 representative images per grade. Physician validators rated volunteers on each scale (2 rounds of live review). Volunteers provided 2 series of self-assessments. Physician and subject intrarater reliability were based on the comparison of round 1 and round 2 scores (mean weighted kappa coefficient). Other measures were physician interrater agreement (intraclass correlation) and subject/physician interrater agreement (Pearson correlation).
[RESULTS] Physician intrarater agreement was almost perfect or substantial (POL, 0.725; OCS, 0.789; POLM, 0.826). Overall, physician interrater agreement was almost perfect for all 3 scales and ranged from moderate to substantial by grade. Subject intrarater agreement and subject/physician interrater agreement were substantial.
[CONCLUSION] All scales demonstrated a high degree of intrarater and interrater reliability during the validation process. Physician concordance was good; subject ratings were reliable and comparable to physician assessments.
[OBJECTIVE] To confirm the reliability of 3 scales for evaluating dermal filler and neurotoxin treatments of the perioral area.
[MATERIALS AND METHODS] Three lip-specific photographic scales were developed from standardized 2-dimensional images to evaluate Perioral Lines at Rest (POL), Oral Commissures (OCS), and Perioral Lines at Maximum Contraction (POLM) severity scales. Each 4-grade scale (none to severe) had 3 representative images per grade. Physician validators rated volunteers on each scale (2 rounds of live review). Volunteers provided 2 series of self-assessments. Physician and subject intrarater reliability were based on the comparison of round 1 and round 2 scores (mean weighted kappa coefficient). Other measures were physician interrater agreement (intraclass correlation) and subject/physician interrater agreement (Pearson correlation).
[RESULTS] Physician intrarater agreement was almost perfect or substantial (POL, 0.725; OCS, 0.789; POLM, 0.826). Overall, physician interrater agreement was almost perfect for all 3 scales and ranged from moderate to substantial by grade. Subject intrarater agreement and subject/physician interrater agreement were substantial.
[CONCLUSION] All scales demonstrated a high degree of intrarater and interrater reliability during the validation process. Physician concordance was good; subject ratings were reliable and comparable to physician assessments.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | dermal filler
|
필러 주입술 | dict | 1 |
MeSH Terms
Beauty; Biocompatible Materials; Cosmetic Techniques; Humans; Image Interpretation, Computer-Assisted; Injections; Lip; Middle Aged; Neurotoxins; Observer Variation; Pilot Projects; Reproducibility of Results; Risk Assessment; Severity of Illness Index; Skin Aging
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Penetrating globe injury following periocular hyaluronic acid filler injection: A case report.
- Choroidal ischemia after self-injection of hyaluronic acid filler.
- Intra-articular therapies for synovial joint dysfunction: a comprehensive integrative review.
- Clinical safety of a low-modification hyaluronic acid filler (MoD 2%) for facial rejuvenation.
- A Fibrous-Porous Microsphere-Based Composite Filler for Synchronized Immediate and Long-Term Soft Tissue Restoration.