Enhancing microvascular anastomoses with the Synovis Coupler device: A retrospective analysis of management of vascular diameter discrepancies.
Abstract
[BACKGROUND AND INTRODUCTION] Microvascular surgery enables complex tissue repairs with free flaps. The Synovis Coupler has streamlined venous anastomoses, improving speed and precision. However, size discrepancies between donor and recipient vessels continue to cause postoperative complications. This study presents our experience in managing caliber discrepancies, optimizing venous flow, reducing thrombosis risk, and improving free flap survival.
[MATERIAL AND METHODS] This retrospective observational study analyzed data from patients undergoing free flap reconstruction between January 2018 and January 2024. A total of 84 microvascular free tissue transfers and 86 venous anastomoses were performed using a mechanical coupler system.
[RESULTS] Eighty-six venous anastomoses were completed, averaging 3.25 min each, with an average coupler size of 2.34 mm. No postoperative returns to the operating room or anastomosis revisions were required. Complications included one infection and one hematoma, both resulting in flap necrosis. The average follow-up was 1.7 years, with no cases of venous ischemia.
[DISCUSSION AND CONCLUSION] Our experience suggests that adapting the vessel lumen may represent a practical option for managing diameter discrepancies when using couplers. The approach appeared to reduce the need for grafts and allowed efficient anastomosis. However, the retrospective design, limited sample size, and lack of a comparative group constrain the strength of these findings. Further prospective studies are warranted to confirm whether this method offers a consistent advantage over established techniques.
[MATERIAL AND METHODS] This retrospective observational study analyzed data from patients undergoing free flap reconstruction between January 2018 and January 2024. A total of 84 microvascular free tissue transfers and 86 venous anastomoses were performed using a mechanical coupler system.
[RESULTS] Eighty-six venous anastomoses were completed, averaging 3.25 min each, with an average coupler size of 2.34 mm. No postoperative returns to the operating room or anastomosis revisions were required. Complications included one infection and one hematoma, both resulting in flap necrosis. The average follow-up was 1.7 years, with no cases of venous ischemia.
[DISCUSSION AND CONCLUSION] Our experience suggests that adapting the vessel lumen may represent a practical option for managing diameter discrepancies when using couplers. The approach appeared to reduce the need for grafts and allowed efficient anastomosis. However, the retrospective design, limited sample size, and lack of a comparative group constrain the strength of these findings. Further prospective studies are warranted to confirm whether this method offers a consistent advantage over established techniques.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | microvascular
|
미세수술 | dict | 3 | |
| 시술 | free flap
|
피판재건술 | dict | 2 | |
| 시술 | flap
|
피판재건술 | dict | 1 | |
| 합병증 | hematoma
|
혈종 | dict | 1 | |
| 합병증 | infection
|
감염 | dict | 1 | |
| 합병증 | flap necrosis
|
괴사 | dict | 1 |
📑 인용 관계
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Endodontic implications of hypercementosis: A systematic review of anatomical challenges and therapeutic strategies.
- Penetrating globe injury following periocular hyaluronic acid filler injection: A case report.
- Breast plastic surgery in perimenopausal and postmenopausal women: Menopause-informed counseling on screening, safety, and long-term breast health.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Free flap reconstruction of a cast-related pressure ulcer in a pediatric patient with spinal muscular atrophy.