Evaluating Osteotomy Accuracy in Mandibular Reconstruction: A Preliminary Study Using Custom Cutting Guides and Virtual Reality.

Diseases (Basel, Switzerland) 2025 Vol.13(3)

Borbon C, Novaresio A, Iocca O, Nonis F, Moos S, Vezzetti E, Ramieri G, Zavattero E

관련 도메인

Abstract

[BACKGROUND] Mandibular reconstruction has evolved significantly since its inception in the early 1900s. Currently, the fibula free flap (FFF) is considered the gold standard for mandibular and maxillary reconstructions, particularly for extensive defects, and the introduction of Extended Reality (XR) and virtual surgical planning (VSP) is revolutionizing maxillofacial surgery.

[METHODS] This study focuses on evaluating the accuracy of using in-house cutting guides for mandibular reconstruction with FFF supported by virtual surgical planning (VSP). Planned and intraoperative osteotomies obtained from postoperative CT scans were compared in 17 patients who met the inclusion criteria. The proposed analysis included measurements of deviation angles, thickness at the centre of gravity, and the maximum thickness of the deviation volume. Additionally, a mandibular resection coding including 12 configurations was defined to classify and analyze the precision of mandibular osteotomies and investigate systematic errors. Preoperative, planned, and postoperative models have been inserted in an interactive VR environment, VieweR, to enhance surgical planning and outcome analysis.

[RESULTS] The results proved the efficiency of adopting customized cutting guides and highlighted the critical role of advanced technologies such as CAD/CAM and VR in modern maxillofacial surgery. A novel coding system including 12 possible configurations was developed to classify and analyze the precision of mandibular osteotomies. This system considers (1) the position of the cutting blade relative to the cutting plane of the mandibular guide; (2) the position of the intersection axis between the planned and intraoperative osteotomy relative to the mandible; (3) the direction of rotation of the intraoperative osteotomy plane around the intersection axis from the upper view of the model.

[CONCLUSIONS] This study demonstrates the accuracy and reliability of in-house cutting guides for mandibular reconstruction using fibula free flaps (FFF) supported by virtual surgical planning (VSP). The comparison between planned and intraoperative osteotomies confirmed the precision of this approach, with minimal deviations observed. These findings highlight the critical role of CAD/CAM and XR technologies in modern maxillofacial surgery, offering improved surgical precision and optimizing patient outcomes.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 free flap 피판재건술 dict 1
해부 fibula scispacy 1
해부 maxillofacial scispacy 1
해부 CAD/CAM scispacy 1
해부 mandible 하악골 dict 1
합병증 mandibular osteotomies scispacy 1
합병증 maxillofacial scispacy 1
합병증 upper scispacy 1
약물 FFF → fibula free flap C5395228
Free fibular flap
scispacy 1
약물 [BACKGROUND] Mandibular scispacy 1
약물 [CONCLUSIONS] scispacy 1
기타 Mandibular scispacy 1
기타 maxillary scispacy 1
기타 patients scispacy 1
기타 VieweR scispacy 1
기타 patient scispacy 1

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문