Model of Arteriovenous Malformation Created in Human Placenta for Training in Vascular Microneurosurgery.
Abstract
[BACKGROUND AND OBJECTIVE] Arteriovenous malformations (AVMs) are congenital lesions, and because of their structure, complexity, flow, size, and location organization, they are lesions that require extensive anatomic knowledge and mastery of microsurgical skills and techniques. Human placentas as a training model for AVM surgery are promising alternatives. This article aims to describe the technique for forming an AVM-type lesion in human placentas and its usefulness in the training of microsurgical treatment techniques.
[METHODS] In this study, 15 fresh human placental models were treated. A nidus was created using synthetic material, and dynamic flow was evaluated with intravascular injection of Indocyanine Green. The catheter system was connected to a continuous flow infusion pump. For simulation purposes, 4 vascular neurosurgeons and 4 vascular neurosurgery fellows used the same techniques and instruments used in real surgery to simulate the resection of AVM lesions. Subjective assessments were conducted, evaluating the validity and structured content on a 5-point Likert scale. Evaluation criteria included the execution of technical maneuvers and the model's expression and structural aspects.
[RESULTS] We describe the step-by-step creation of an AVM in a placental biological model for the performance of vascular microsurgery training in the laboratory. We created in the human placenta a lesion with the characteristics of an AVM for microsurgical training in the laboratory, which presents key features realistic to a real AVM, such as 1 or more feeder arteries, nidus (synthetic), draining vein(s), continuous and pulsatile flow, and 3-dimensional configuration. Furthermore, it demonstrates the applicability of microsurgical techniques to the model compared with performing surgery on a patient.
[CONCLUSION] Considering it an effective method for laboratory training, the creation of arteriovenous malformations in human placentas enables students to replicate, comprehend the structure, and master microsurgical techniques in a realistic model.
[METHODS] In this study, 15 fresh human placental models were treated. A nidus was created using synthetic material, and dynamic flow was evaluated with intravascular injection of Indocyanine Green. The catheter system was connected to a continuous flow infusion pump. For simulation purposes, 4 vascular neurosurgeons and 4 vascular neurosurgery fellows used the same techniques and instruments used in real surgery to simulate the resection of AVM lesions. Subjective assessments were conducted, evaluating the validity and structured content on a 5-point Likert scale. Evaluation criteria included the execution of technical maneuvers and the model's expression and structural aspects.
[RESULTS] We describe the step-by-step creation of an AVM in a placental biological model for the performance of vascular microsurgery training in the laboratory. We created in the human placenta a lesion with the characteristics of an AVM for microsurgical training in the laboratory, which presents key features realistic to a real AVM, such as 1 or more feeder arteries, nidus (synthetic), draining vein(s), continuous and pulsatile flow, and 3-dimensional configuration. Furthermore, it demonstrates the applicability of microsurgical techniques to the model compared with performing surgery on a patient.
[CONCLUSION] Considering it an effective method for laboratory training, the creation of arteriovenous malformations in human placentas enables students to replicate, comprehend the structure, and master microsurgical techniques in a realistic model.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | microsurgery
|
미세수술 | dict | 1 | |
| 해부 | intravascular
|
scispacy | 1 | ||
| 합병증 | AVMs
→ Arteriovenous malformations
|
scispacy | 1 | ||
| 합병증 | lesions
|
scispacy | 1 | ||
| 합병증 | AVM
|
scispacy | 1 | ||
| 합병증 | draining vein(s
|
scispacy | 1 | ||
| 합병증 | arteriovenous malformations
|
scispacy | 1 | ||
| 약물 | Indocyanine
|
scispacy | 1 | ||
| 약물 | Arteriovenous
|
scispacy | 1 | ||
| 약물 | [BACKGROUND AND OBJECTIVE] Arteriovenous malformations
|
scispacy | 1 | ||
| 질환 | Arteriovenous Malformation
|
C0003857
Congenital arteriovenous malformation
|
scispacy | 1 | |
| 질환 | Arteriovenous malformations
|
C0003857
Congenital arteriovenous malformation
|
scispacy | 1 | |
| 질환 | AVMs
→ Arteriovenous malformations
|
C0003857
Congenital arteriovenous malformation
|
scispacy | 1 | |
| 질환 | congenital lesions
|
scispacy | 1 | ||
| 질환 | AVM
|
C0003857
Congenital arteriovenous malformation
|
scispacy | 1 | |
| 기타 | Human Placenta
|
scispacy | 1 | ||
| 기타 | Vascular
|
scispacy | 1 | ||
| 기타 | Human placentas
|
scispacy | 1 | ||
| 기타 | human placental
|
scispacy | 1 | ||
| 기타 | feeder arteries
|
scispacy | 1 |
MeSH Terms
Humans; Pregnancy; Microsurgery; Female; Placenta; Neurosurgical Procedures; Intracranial Arteriovenous Malformations; Models, Anatomic; Arteriovenous Malformations
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Endodontic implications of hypercementosis: A systematic review of anatomical challenges and therapeutic strategies.
- Breast plastic surgery in perimenopausal and postmenopausal women: Menopause-informed counseling on screening, safety, and long-term breast health.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Free flap reconstruction of a cast-related pressure ulcer in a pediatric patient with spinal muscular atrophy.
- Characterization of Trimmed Nerve Morphology Using High-Resolution Imaging: Comparison of Three Surgical Instruments.