A Comparison of Commercially Available Digital Microscopes for Their Use in Bench-Model Simulation of Microsurgery.
Abstract
[BACKGROUND] Surgical education has seen a transition in the delivery of training, with increased use of online platforms to facilitate remote learning. Simulation training can increase access to education and reduce cost implications, while reducing patient risk. This study aims to compare commercially available digital microscopes, alongside a standard binocular surgical microscope, and determine whether they can be used as an alternative tool for remote microsurgery simulation.
[METHODS] Data were collected for a total of four microscopes, including three commercially available digital microscopes, smartphone, and a binocular table microscope. Product characteristics were collated, and a subjective assessment was conducted using an 11-criteria questionnaire, graded with a 5-point scale. Results of digital microscopes were compared with the table binocular microscope.The Kruskal-Wallis test was used to compare the performance of digital microscopes to the standard binocular microscope RESULTS: The questionnaire was completed by 31 participants: two consultants, nine surgical registrars, fourteen junior trainees, and six medical students. Digital microscopes were found to be significantly more affordable and convenient for trainees; however, the cost of the smartphone was significant. Overall, the Pancellant Digital Microscope performed the poorest, with trainees commenting on its unsuitability for surgical practice; the Plugable USB Digital Microscope (PLDM) was rated overall most like the binocular table microscope. The Depth of field was shallow in all digital microscopes.
[CONCLUSION] With the increasing role of remote learning and simulation training in surgical education, the PLDM can provide a cheaper, more accessible alternative for junior trainees, in their pursuit of microsurgical skill acquisition.
[METHODS] Data were collected for a total of four microscopes, including three commercially available digital microscopes, smartphone, and a binocular table microscope. Product characteristics were collated, and a subjective assessment was conducted using an 11-criteria questionnaire, graded with a 5-point scale. Results of digital microscopes were compared with the table binocular microscope.The Kruskal-Wallis test was used to compare the performance of digital microscopes to the standard binocular microscope RESULTS: The questionnaire was completed by 31 participants: two consultants, nine surgical registrars, fourteen junior trainees, and six medical students. Digital microscopes were found to be significantly more affordable and convenient for trainees; however, the cost of the smartphone was significant. Overall, the Pancellant Digital Microscope performed the poorest, with trainees commenting on its unsuitability for surgical practice; the Plugable USB Digital Microscope (PLDM) was rated overall most like the binocular table microscope. The Depth of field was shallow in all digital microscopes.
[CONCLUSION] With the increasing role of remote learning and simulation training in surgical education, the PLDM can provide a cheaper, more accessible alternative for junior trainees, in their pursuit of microsurgical skill acquisition.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | microsurgery
|
미세수술 | dict | 2 | |
| 약물 | [BACKGROUND]
|
scispacy | 1 | ||
| 약물 | PLDM
→ Plugable USB Digital Microscope
|
scispacy | 1 | ||
| 기타 | patient
|
scispacy | 1 |
MeSH Terms
Microsurgery; Humans; Microscopy; Simulation Training; Clinical Competence; Surveys and Questionnaires; Smartphone
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Endodontic implications of hypercementosis: A systematic review of anatomical challenges and therapeutic strategies.
- Breast plastic surgery in perimenopausal and postmenopausal women: Menopause-informed counseling on screening, safety, and long-term breast health.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Free flap reconstruction of a cast-related pressure ulcer in a pediatric patient with spinal muscular atrophy.
- Characterization of Trimmed Nerve Morphology Using High-Resolution Imaging: Comparison of Three Surgical Instruments.