Awake microsurgical management of brain aneurysms: a comprehensive systematic review and meta-analysis on rationale, safety and clinical outcomes.

Neuro-Chirurgie 2024 Vol.70(6) p. 101600

Bocanegra-Becerra JE, Simoni G, Mendieta CD, Acha Sánchez JL, Palavani LB, Wouters K, Punukollu A, Mangas G, Bertani R, Lopez-Gonzalez MA

관련 도메인

Abstract

[INTRODUCTION] Awake microsurgery for brain aneurysm treatment has emerged as a tool for real-time intraoperative monitoring, opportune detection of ischemic complications, and reduction of surgical morbidity. Herein, we aimed to explore the current state of the procedure's rationale, safety and clinical outcomes.

[METHODS] In accordance with PRISMA guidelines, five databases were queried for articles reporting awake microsurgical management of brain aneurysms. Aggregate study results were combined using random-effects meta-analyses. Publication bias was evaluated through funnel plot analysis and Egger's regression test.

[RESULTS] Out of 847 articles, 11 records satisfied the inclusion criteria. Seventy-five patients (68% female) with 75 brain aneurysms (68% unruptured) were analyzed. Clipping was the predominant technique (58%), followed by bypass (17%). Monitored anesthesia care was the principal anesthesia protocol (60%). The incidence of anesthesia-related complications was 1% [95%CI, 0.00-0.05, I = 19%], and the conversion rate from an awake-induced anesthesia protocol to general anesthesia was 1% [95%CI, 0.00-0.05, I = 0%]. No permanent anesthesia-related morbidity and mortality was reported. Complete aneurysm repair, occlusion and bypass patency rate was 100% [95%CI, 0.96-1.00, I = 0%]. The transient postoperative symptomatic event rate was 34% [95%CI, 0.06-0.81, I = 77%]. The overall morbidity rate was 4% [95%CI, 0.00-0.09, I = 0%], and the overall mortality rate was 0% [95%CI, 0.00-0.03, I = 0%].

[CONCLUSION] Awake microsurgery of brain aneurysms is feasible, yet current evidence stems from observational studies. This procedure can reduce surgical morbidity by providing accurate and real-time neurological monitoring during aneurysm repair. While this technique appears to be tolerated, higher level evidence is needed to evaluate judiciously its safety and preference over existing practices for intraoperative neurological monitoring.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
시술 microsurgery 미세수술 dict 2
해부 brain scispacy 1
합병증 brain aneurysms scispacy 1
합병증 aneurysm scispacy 1
약물 [INTRODUCTION] scispacy 1
질환 brain aneurysms C0751003
Brain Aneurysm
scispacy 1
질환 brain aneurysm C0751003
Brain Aneurysm
scispacy 1
질환 aneurysm C0002940
Aneurysm
scispacy 1
질환 occlusion C0001168
Complete obstruction
scispacy 1
기타 patients scispacy 1

MeSH Terms

Female; Humans; Male; Intracranial Aneurysm; Microsurgery; Monitoring, Intraoperative; Neurosurgical Procedures; Treatment Outcome; Wakefulness

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문