Remote Monitoring System for Condition Management of Patients in Free Flap Surgery.
Abstract
[INTRODUCTION] Free flap surgery is inconvenient because an attending physician must observe a patient's condition every day to ensure that normal tissue is restored within 72 h after the surgery. To address this problem, this paper proposes a remote monitoring technology to observe a patient's condition in real time.
[METHODS] To design a monitoring system, the camera consists of MCU board, DC-DC converter, alarm performance, Wi-fil module, and server, and the camera and MCU part is connected to the server through the wi-fi network. A camera obtains the images of the surgical site once every 2 s, and the images are transmitted to the attending physician or nurse via Wi-Fi communication. The working distance between camera and surgical site is 56 cm, and the viewing angle of a camera is 60° (radius).
[RESULTS] A video shooting test is also performed, in which the images are obtained once per hour between 17:00 and 08:00 the next day; the results show that high-quality images are obtained in the video shooting test. The imaging error is zero (0 GB) in the video shooting test results.
[DISCUSSION AND CONCLUSION] The imaging of the surgical site can be obtained by camera system, and the proposed method is that there no storage error occurs during the shooting process. In addition, the shooting performance has high velocity. It is possible to control the WD according to a patient's body via a holding manipulator used for the camera. The new method is expected to be used for remote patient management, for a wide range of procedures, in the medical field.
[METHODS] To design a monitoring system, the camera consists of MCU board, DC-DC converter, alarm performance, Wi-fil module, and server, and the camera and MCU part is connected to the server through the wi-fi network. A camera obtains the images of the surgical site once every 2 s, and the images are transmitted to the attending physician or nurse via Wi-Fi communication. The working distance between camera and surgical site is 56 cm, and the viewing angle of a camera is 60° (radius).
[RESULTS] A video shooting test is also performed, in which the images are obtained once per hour between 17:00 and 08:00 the next day; the results show that high-quality images are obtained in the video shooting test. The imaging error is zero (0 GB) in the video shooting test results.
[DISCUSSION AND CONCLUSION] The imaging of the surgical site can be obtained by camera system, and the proposed method is that there no storage error occurs during the shooting process. In addition, the shooting performance has high velocity. It is possible to control the WD according to a patient's body via a holding manipulator used for the camera. The new method is expected to be used for remote patient management, for a wide range of procedures, in the medical field.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | free flap
|
피판재건술 | dict | 2 | |
| 해부 | Flap
|
scispacy | 1 | ||
| 해부 | tissue
|
scispacy | 1 | ||
| 약물 | [INTRODUCTION] Free
|
scispacy | 1 | ||
| 약물 | MCU
|
scispacy | 1 | ||
| 약물 | [RESULTS] A
|
scispacy | 1 | ||
| 기타 | Patients
|
scispacy | 1 | ||
| 기타 | patient
|
scispacy | 1 |
MeSH Terms
Humans; Free Tissue Flaps; Communication
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Endodontic implications of hypercementosis: A systematic review of anatomical challenges and therapeutic strategies.
- Breast plastic surgery in perimenopausal and postmenopausal women: Menopause-informed counseling on screening, safety, and long-term breast health.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Free flap reconstruction of a cast-related pressure ulcer in a pediatric patient with spinal muscular atrophy.
- Characterization of Trimmed Nerve Morphology Using High-Resolution Imaging: Comparison of Three Surgical Instruments.