Mandibular reconstructions with free fibula flap using standardized partially adjustable cutting guides or CAD/CAM technique: a three- and two-dimensional comparison.
Abstract
[BACKGROUND] Mandibular reconstruction with the fibula free flap (FFF) is performed freehand, CAD/CAM-assisted, or by using partially adjustable resection/reconstruction aids. The two latter options represent the contemporary reconstructive solutions of the recent decade. The purpose of this study was to compare both auxiliary techniques with regard to feasibility, accuracy, and operative parameters.
[METHODS AND MATERIALS] The first twenty consecutively operated patients requiring a mandibular reconstruction (within angle-to-angle) with the FFF using the partially adjustable resection aids between January 2017 and December 2019 at our department were included. Additionally, matching CAD/CAM FFF cases were used as control group in this cross-sectional study. Medical records and general information (sex, age, indication for surgery, extent of resection, number of segments, duration of surgery, and ischemia time) were analyzed. In addition, the pre- and postoperative Digital Imaging and Communications in Medicine data of the mandibles were converted to standard tessellation language (.stl) files. Conventional measurements - six horizontal distances (A-F) and temporo-mandibular joint (TMJ) spaces - and the root mean square error (RMSE) for three-dimensional analysis were measured and calculated.
[RESULTS] In total, 40 patients were enrolled (20:20). Overall operation time, ischemia time, and the interval between ischemia time start until end of operation showed no significant differences. No significant difference between the two groups were revealed in conventional measurements of distances (A-D) and TMJ spaces. The Δ differences for the distance F (between the mandibular foramina) and the right medial joint space were significantly lower in the ReconGuide group. The RMSE analysis of the two groups showed no significant difference (=0.925), with an overall median RMSE of 3.1 mm (2.2-3.7) in the CAD/CAM and 2.9 mm (2.2-3.8) in the ReconGuide groups.
[CONCLUSIONS] The reconstructive surgeon can achieve comparable postoperative results regardless of technique, which may favor the ReconGuide use in mandibular angle-to-angle reconstruction over the CAD/CAM technique because of less preoperative planning time and lower costs per case.
[METHODS AND MATERIALS] The first twenty consecutively operated patients requiring a mandibular reconstruction (within angle-to-angle) with the FFF using the partially adjustable resection aids between January 2017 and December 2019 at our department were included. Additionally, matching CAD/CAM FFF cases were used as control group in this cross-sectional study. Medical records and general information (sex, age, indication for surgery, extent of resection, number of segments, duration of surgery, and ischemia time) were analyzed. In addition, the pre- and postoperative Digital Imaging and Communications in Medicine data of the mandibles were converted to standard tessellation language (.stl) files. Conventional measurements - six horizontal distances (A-F) and temporo-mandibular joint (TMJ) spaces - and the root mean square error (RMSE) for three-dimensional analysis were measured and calculated.
[RESULTS] In total, 40 patients were enrolled (20:20). Overall operation time, ischemia time, and the interval between ischemia time start until end of operation showed no significant differences. No significant difference between the two groups were revealed in conventional measurements of distances (A-D) and TMJ spaces. The Δ differences for the distance F (between the mandibular foramina) and the right medial joint space were significantly lower in the ReconGuide group. The RMSE analysis of the two groups showed no significant difference (=0.925), with an overall median RMSE of 3.1 mm (2.2-3.7) in the CAD/CAM and 2.9 mm (2.2-3.8) in the ReconGuide groups.
[CONCLUSIONS] The reconstructive surgeon can achieve comparable postoperative results regardless of technique, which may favor the ReconGuide use in mandibular angle-to-angle reconstruction over the CAD/CAM technique because of less preoperative planning time and lower costs per case.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | free flap
|
피판재건술 | dict | 1 | |
| 시술 | flap
|
피판재건술 | dict | 1 | |
| 해부 | Mandibular
|
scispacy | 1 | ||
| 해부 | fibula
|
scispacy | 1 | ||
| 해부 | mandibles
|
scispacy | 1 | ||
| 해부 | TMJ
→ temporo-mandibular joint
|
scispacy | 1 | ||
| 약물 | FFF
→ fibula free flap
|
C5395228
Free fibular flap
|
scispacy | 1 | |
| 약물 | [BACKGROUND] Mandibular
|
scispacy | 1 | ||
| 약물 | [RESULTS]
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS] The
|
scispacy | 1 | ||
| 질환 | ischemia
|
C0022116
Ischemia
|
scispacy | 1 | |
| 기타 | fibula flap
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 | ||
| 기타 | A-F
|
scispacy | 1 | ||
| 기타 | temporo-mandibular joint
|
scispacy | 1 | ||
| 기타 | mandibular foramina
|
scispacy | 1 | ||
| 기타 | ReconGuide
|
scispacy | 1 |
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Endodontic implications of hypercementosis: A systematic review of anatomical challenges and therapeutic strategies.
- Breast plastic surgery in perimenopausal and postmenopausal women: Menopause-informed counseling on screening, safety, and long-term breast health.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Free flap reconstruction of a cast-related pressure ulcer in a pediatric patient with spinal muscular atrophy.
- Characterization of Trimmed Nerve Morphology Using High-Resolution Imaging: Comparison of Three Surgical Instruments.