Comparison of a Novel Static Computer-aided Surgical and Freehand Techniques for Osteotomy and Root-end Resection.
Abstract
[INTRODUCTION] This study compared the accuracy and efficiency of a novel static computer-aided surgical technique using a 3-dimensional (3D)-printed surgical guide (3D-SG) with a fully guided drill protocol (3D-SG FG) to the freehand (FH) osteotomy and root-end resection (RER).
[METHODS] Forty-six roots from 2 cadaver heads were divided into 2 groups: 3D-SG FG (n = 23) and FH (n = 23). Cone-beam computed tomographic scans were taken preoperatively and postoperatively. The endodontic microsurgery was planned in Blue Sky Bio software, and the 3D-SG was designed and 3D printed. The osteotomy and RER were conducted using a guided twist drill diameter of 2 mm and an ascending tapered drill with diameters of 2.8/3.2, 3.2/3.6, 3.8/4.2, and 4.2 mm with respective guided drill guides. Two-dimensional and three-dimensional virtual deviations and angular deflection were calculated. Linear osteotomy measures and root resection angle were obtained. The osteotomy and RER time and the number of mishaps were recorded.
[RESULTS] Two-dimensional and three-dimensional accuracy deviations and angular deflection were lower in the 3D-SG FG protocol than in the FH technique (P < .05). The height, length, and depth of the osteotomy and root resection angle were less in the 3D-SG FG protocol than in the FH technique (P < .05). The osteotomy and RER time with the 3D-SG FG protocol were less than the FH method (P < .05).
[CONCLUSIONS] Within the limitations of this cadaver-based study using denuded maxillary and mandibular jaws, 3D-SG FG protocol showed higher accuracy than FH osteotomy and RER. Moreover, the 3D-SG FG drill protocol significantly reduced the surgical time.
[METHODS] Forty-six roots from 2 cadaver heads were divided into 2 groups: 3D-SG FG (n = 23) and FH (n = 23). Cone-beam computed tomographic scans were taken preoperatively and postoperatively. The endodontic microsurgery was planned in Blue Sky Bio software, and the 3D-SG was designed and 3D printed. The osteotomy and RER were conducted using a guided twist drill diameter of 2 mm and an ascending tapered drill with diameters of 2.8/3.2, 3.2/3.6, 3.8/4.2, and 4.2 mm with respective guided drill guides. Two-dimensional and three-dimensional virtual deviations and angular deflection were calculated. Linear osteotomy measures and root resection angle were obtained. The osteotomy and RER time and the number of mishaps were recorded.
[RESULTS] Two-dimensional and three-dimensional accuracy deviations and angular deflection were lower in the 3D-SG FG protocol than in the FH technique (P < .05). The height, length, and depth of the osteotomy and root resection angle were less in the 3D-SG FG protocol than in the FH technique (P < .05). The osteotomy and RER time with the 3D-SG FG protocol were less than the FH method (P < .05).
[CONCLUSIONS] Within the limitations of this cadaver-based study using denuded maxillary and mandibular jaws, 3D-SG FG protocol showed higher accuracy than FH osteotomy and RER. Moreover, the 3D-SG FG drill protocol significantly reduced the surgical time.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | microsurgery
|
미세수술 | dict | 1 | |
| 해부 | roots
|
scispacy | 1 | ||
| 해부 | maxillary
|
scispacy | 1 | ||
| 해부 | mandibular jaws
|
scispacy | 1 | ||
| 약물 | [INTRODUCTION]
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS]
|
scispacy | 1 | ||
| 기타 | Blue Sky
|
scispacy | 1 |
MeSH Terms
Humans; Printing, Three-Dimensional; Osteotomy; Maxilla; Cone-Beam Computed Tomography; Cadaver; Computers; Surgery, Computer-Assisted; Computer-Aided Design
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Endodontic implications of hypercementosis: A systematic review of anatomical challenges and therapeutic strategies.
- Breast plastic surgery in perimenopausal and postmenopausal women: Menopause-informed counseling on screening, safety, and long-term breast health.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Free flap reconstruction of a cast-related pressure ulcer in a pediatric patient with spinal muscular atrophy.
- Characterization of Trimmed Nerve Morphology Using High-Resolution Imaging: Comparison of Three Surgical Instruments.