Micro-Rheological Changes of Red Blood Cells in the Presence of an Arterio-Venous Fistula or a Loop-Shaped Venous Graft in the Rat.

Frontiers in physiology 2020 Vol.11() p. 616528

Szabo B, Tanczos B, Varga A, Barath B, Ghanem S, Rezsabek Z, Al-Smadi MW, Nemeth N

Abstract

In case of kidney failure, hemodialysis is the primary kidney replacement technique. Several vascular access methods used for the therapy, one of which is the arterio-venous fistula (AVF). In the AVF, the blood flow is altered, which can elevate the mechanical stress on the red blood cells (RBCs). This can affect the RBC hemorheological properties, and it can further cause systemic changes. To lower the turbulence and shear stress, we performed a loop-shaped arterio-arterial venous interposition graft (loop-shaped graft) to compare its effect to the conventional AVF. Thirty male Wistar were used (permission registration Nr.: 25/2016/UDCAW). The animals were randomly divided into sham-operated, AVF, and loop groups ( = 10/each). The superficial inferior epigastric vein (SIEV) was used to create the AVF and the loop-shaped graft. Blood samples were taken before/after the surgery and at the 1st, 3rd, and 5th postoperative weeks. We measured hemorhelogical, hematological, and blood gas parameters. The microcirculation of the hind limbs was also monitored using Laser Doppler fluxmetry. Hematocrit, RBC count, and hemoglobin decreased by the 1st postoperative week. The erythrocyte aggregation values significantly increased in the fistula group by the 5th week (6.43 ± 2.31 vs. 13.60; < 0.0001; vs. before operation). At the postoperative 1st week in the loop group, the values showed a significant decrease in RBC deformability. During the maturation period, dominantly at the 5th week, all values were normalized. The operated hind limb's skin microcirculation significantly increased in the sham and loop group by the 1st week (39 ± 10.57 vs. 73.93 ± 1.97 BFU, < 0.01). This increase wasn't observed in the fistula group probably due to a steal-effect. Unlike in the loop group, in the presence of the fistula, several rheological parameters have changed. The loop-shaped graft had only minimal impact on micro-rheological parameters.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 Red Blood Cells scispacy 1
해부 kidney scispacy 1
해부 blood scispacy 1
해부 blood cells scispacy 1
해부 RBCs → red blood cells scispacy 1
해부 RBC scispacy 1
해부 graft scispacy 1
해부 SIEV → superficial inferior epigastric vein scispacy 1
해부 hind limbs scispacy 1
해부 erythrocyte scispacy 1
해부 hind limb scispacy 1
해부 skin scispacy 1
합병증 Graft scispacy 1
합병증 arterio-venous fistula scispacy 1
합병증 AVF → arterio-venous fistula scispacy 1
질환 Arterio-Venous Fistula C0003855
Arteriovenous fistula
scispacy 1
질환 kidney failure C0035078
Kidney Failure
scispacy 1
질환 AVF → arterio-venous fistula C0003855
Arteriovenous fistula
scispacy 1
질환 erythrocyte aggregation C0014766
Erythrocyte aggregation measurement
scispacy 1
질환 fistula C0016169
pathologic fistula
scispacy 1
질환 Blood samples scispacy 1
기타 vascular scispacy 1
기타 arterio-arterial venous scispacy 1
기타 Wistar scispacy 1
기타 sham-operated scispacy 1
기타 superficial inferior epigastric vein scispacy 1
기타 hemoglobin scispacy 1