High definition three-dimensional exoscope (VITOM 3D) for microsurgery training: a preliminary experience.
Abstract
[PURPOSE] To assess the feasibility of a high definition 3D exoscope (VITOM) for microsurgery training in a cohort of naïve medical students.
[METHODS] Twenty-two consecutive medical students performed a battery of four exercises assessing basic microsurgical skills. The students were randomized in two different groups based on two different VITOM holding systems (VERSACRANE™ and ARTip™ cruise). Participants self-reported the VITOM system quality on a 4-point Likert scale (VITOM Quality Assessment Tool). The time needed to complete the exercises was analyzed.
[RESULTS] All students successfully completed the training, and no technical issues were raised during the simulation. The majority of the individual items were judged "good" or "very good" (n = 187; 94.4%), regardless of the two groups. "Image quality" (n = 21; 95%), "magnification rate" (n = 20; 91%), "stereoscopic effect" (n = 19; 86%), and "focusing" (n = 18; 82%) represented the best-rated items. No statistically significant difference between the two groups was measured in almost all items of the VITOM Quality Assessment Tool (p > 0.05). The time needed to perform each exercise showed a statistically significant difference between groups in two tests (p < 0.05).
[CONCLUSION] This study demonstrated the feasibility of a VITOM-based microsurgery training. The students' subjective assessment of the VITOM 3D system was promising in terms of technological quality and technical feasibility. Further studies are recommended to define which VITOM holding system could be more appropriate for microsurgery training.
[METHODS] Twenty-two consecutive medical students performed a battery of four exercises assessing basic microsurgical skills. The students were randomized in two different groups based on two different VITOM holding systems (VERSACRANE™ and ARTip™ cruise). Participants self-reported the VITOM system quality on a 4-point Likert scale (VITOM Quality Assessment Tool). The time needed to complete the exercises was analyzed.
[RESULTS] All students successfully completed the training, and no technical issues were raised during the simulation. The majority of the individual items were judged "good" or "very good" (n = 187; 94.4%), regardless of the two groups. "Image quality" (n = 21; 95%), "magnification rate" (n = 20; 91%), "stereoscopic effect" (n = 19; 86%), and "focusing" (n = 18; 82%) represented the best-rated items. No statistically significant difference between the two groups was measured in almost all items of the VITOM Quality Assessment Tool (p > 0.05). The time needed to perform each exercise showed a statistically significant difference between groups in two tests (p < 0.05).
[CONCLUSION] This study demonstrated the feasibility of a VITOM-based microsurgery training. The students' subjective assessment of the VITOM 3D system was promising in terms of technological quality and technical feasibility. Further studies are recommended to define which VITOM holding system could be more appropriate for microsurgery training.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | microsurgery
|
미세수술 | dict | 4 | |
| 약물 | VERSACRANE
|
scispacy | 1 |
MeSH Terms
Humans; Microsurgery
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Endodontic implications of hypercementosis: A systematic review of anatomical challenges and therapeutic strategies.
- Breast plastic surgery in perimenopausal and postmenopausal women: Menopause-informed counseling on screening, safety, and long-term breast health.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Free flap reconstruction of a cast-related pressure ulcer in a pediatric patient with spinal muscular atrophy.
- Characterization of Trimmed Nerve Morphology Using High-Resolution Imaging: Comparison of Three Surgical Instruments.