Clinical Impact of DIEP Flap Perforator Characteristics - A Prospective Indocyanine Green Fluorescence Imaging Study.
Abstract
[BACKGROUND] The question to what extent perfusion in deep inferior epigastric perforator (DIEP) flaps depends on specific perforator characteristics has been raised. Anatomical studies and previous clinical trials focussing on DIEP flap perfusion resulted in discrepancies. This prospective study investigates how perforator row, number and diameter affect DIEP flap microperfusion via Indocyanine Green (ICG) fluorescence angiography.
[METHODS] The fractional weight of insufficiently perfused flap tissue in Zone 4 related to the total DIEP flap weight was measured based on ICG fluorescence angiography and defined as Zone 4 %. As a surrogate for overall DIEP flap perfusion, Zone 4 % was assessed according to the row, number and diameter of perforators included in the flap.
[RESULTS] In 42 unilateral DIEP flap breast reconstructions, neither medial (33.6 ± 14.2 %)/lateral perforator row (29.9 ± 7.5 %, p = 0.683) nor the parameter perforator number (single perforator 31.5 ± 14.4 %, two perforators 30.2 ± 10.2 %, p = 0.727) had a statistically significant effect on flap tissue availability as measured via Zone 4 %. A negative correlative trend between perforator diameter and Zone 4 % (r = -0.096, p = 0.588) was observed.
[CONCLUSION] Zone 4 % provides a novel method for an objective assessment of DIEP flap perfusion. Medial/lateral row selection and other perforator properties (number, diameter) within the standard ranges, did not affect Zone 4 % as indicated by ICG fluorescence angiography.
[METHODS] The fractional weight of insufficiently perfused flap tissue in Zone 4 related to the total DIEP flap weight was measured based on ICG fluorescence angiography and defined as Zone 4 %. As a surrogate for overall DIEP flap perfusion, Zone 4 % was assessed according to the row, number and diameter of perforators included in the flap.
[RESULTS] In 42 unilateral DIEP flap breast reconstructions, neither medial (33.6 ± 14.2 %)/lateral perforator row (29.9 ± 7.5 %, p = 0.683) nor the parameter perforator number (single perforator 31.5 ± 14.4 %, two perforators 30.2 ± 10.2 %, p = 0.727) had a statistically significant effect on flap tissue availability as measured via Zone 4 %. A negative correlative trend between perforator diameter and Zone 4 % (r = -0.096, p = 0.588) was observed.
[CONCLUSION] Zone 4 % provides a novel method for an objective assessment of DIEP flap perfusion. Medial/lateral row selection and other perforator properties (number, diameter) within the standard ranges, did not affect Zone 4 % as indicated by ICG fluorescence angiography.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | diep flap
|
피판재건술 | dict | 7 | |
| 시술 | flap
|
피판재건술 | dict | 3 | |
| 해부 | flap tissue
|
scispacy | 1 | ||
| 해부 | medial
|
scispacy | 1 | ||
| 해부 | breast
|
유방 | dict | 1 | |
| 합병증 | perforator
|
scispacy | 1 | ||
| 합병증 | perforators
|
scispacy | 1 | ||
| 약물 | Indocyanine Green
|
C0021234
indocyanine green
|
scispacy | 1 | |
| 약물 | Indocyanine
|
scispacy | 1 | ||
| 약물 | [BACKGROUND]
|
scispacy | 1 | ||
| 약물 | ICG
→ Indocyanine Green
|
scispacy | 1 | ||
| 약물 | [RESULTS] In
|
scispacy | 1 | ||
| 약물 | [CONCLUSION] Zone 4
|
scispacy | 1 | ||
| 기타 | DIEP Flap Perforator
|
scispacy | 1 | ||
| 기타 | perforators
|
scispacy | 1 | ||
| 기타 | perforator
|
scispacy | 1 |
MeSH Terms
Breast Neoplasms; Computed Tomography Angiography; Epigastric Arteries; Female; Fluorescence; Humans; Indocyanine Green; Mammaplasty; Middle Aged; Perforator Flap; Prospective Studies
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- From Palliation After Angiosarcoma Resection to Totally Autologous Aesthetic Breast Reconstruction Combining Kiss Latissimus Dorsi Flap and Contralateral Breast Sharing Internal Mammary Artery Perforator Flap: A Case Report.
- Case report of a rare soft tissue tuberculosis in a patient undergoing lipoabdominoplasty.