Restoring Symmetry in Challenging Revision Breast Surgery: Outcomes of Pilot Study with Poly-4-Hydroxybutyrate Implant Construct.

Plastic and reconstructive surgery. Global open 2026 Vol.14(3) p. e7549

Sorenson TJ, Boyd CJ, Hemal K, Cohen O, Choi M, Karp N

관련 도메인

Abstract

[BACKGROUND] Revision breast reconstruction is often necessary to address complications, reduce asymmetry, or improve the aesthetic result. Our previously described use of poly-4-hydroxybutyrate (P4HB) has shown promise in primary reconstruction; limited data exist on its use in revision surgery. This study presented a single-institution case series evaluating indications and outcomes of revision breast reconstruction using a P4HB-wrapped implant.

[METHODS] We retrospectively reviewed patients who underwent breast reconstruction revision with a P4HB-wrapped implant at our institution from September 2022 to May 2025. Data were collected through chart review.

[RESULTS] Thirty-four patients (51 breasts) underwent revision surgery using a P4HB-wrapped implant. Most patients (85%) had 2-stage reconstructions. Most primary reconstructions (76%) occurred at our institution, with 96% continuity among reconstructive surgeons. Median (interquartile range) time from initial reconstruction to revision was 344 (609) days. The most common indication was radiation-associated breast asymmetry (35%). At a median (interquartile range) follow-up of 501 (410) days, 91% (31 of 34) of patients maintained stable breast symmetry. Complications occurred in 5.9% (3 of 51) of breasts: 1 implant exposure requiring explantation (1.96%) and 2 cases of persistent malposition (3.92%) despite P4HB use.

[CONCLUSIONS] The P4HB-wrapped implants achieved consistent soft-tissue support and maintained symmetry during the observed follow-up period, and for the limited number of patients studied, radiation-associated capsular contracture or shape changes were not observed during the study period. These findings support P4HB as a valuable adjunct in complex revisions, particularly in patients with prior radiation or significant asymmetry. Ongoing follow-up is needed to assess the long-term durability and aesthetic outcomes of this approach.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 breast 유방 dict 6
합병증 asymmetry 비대칭 dict 3
해부 breasts: 1 implant scispacy 1
합병증 capsular contracture 피막구축 dict 1
약물 Poly-4-Hydroxybutyrate C3880547
Polyhydroxybutyrate suture
scispacy 1
약물 breasts C0006141
Breast
scispacy 1
약물 [BACKGROUND] Revision scispacy 1
약물 [CONCLUSIONS] scispacy 1
질환 contracture C0009917
Contracture
scispacy 1
질환 soft-tissue scispacy 1
기타 P4HB → poly-4-hydroxybutyrate scispacy 1
기타 patients scispacy 1
기타 capsular scispacy 1

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문