Intraoperative Evaluation of Textured Anatomical Implant Rotation: A Prospective Study.

Plastic and reconstructive surgery 2024 Vol.154(3) p. 490-499

Gary CS, Kirloskar KM, Koh MJ, Abadeer AI, Wang JS, Del Corral G, Fan KL, Song DH

관련 도메인

Abstract

[BACKGROUND] Textured implants were developed with the goal of reducing rates of capsular contracture and preventing implant malposition (eg, malrotation). Recent evidence has questioned whether textured implants are as resistant to malrotation as previously reported.

[METHODS] Women presenting to a single health care system for removal of textured implants were prospectively enrolled in the study from September of 2019 to July of 2022. Patients who underwent removal of an anatomical, textured implant in the operating room were included in the study; whereas those who did not undergo implant removal, or were found to have a smooth implant, or a round, textured implant, were excluded. The degree of implant rotation on removal of the implant was measured intraoperatively. Information regarding implant-specific factors, patient demographics, clinical factors, and operative characteristics, was collected.

[RESULTS] A total of 51 patients (80 implants) were included in the study; 45% of implants were malrotated (rotated >30 degrees), and the median degree of rotation was 30 degrees. Having more than one previous revision of the breast pocket was predictive of implant rotation (42 degrees) on multivariate linear regression analysis. Patients who presented with a complaint of "aesthetic dissatisfaction" had 2.89 increased odds of having an implant rotated greater than 30 degrees.

[CONCLUSION] The authors' study found a high rate of malrotation of textured shaped implants on explantation.

[CLINICAL QUESTION/LEVEL OF EVIDENCE] Risk, III.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 breast 유방 dict 1
해부 smooth scispacy 1
합병증 capsular contracture 피막구축 dict 1
합병증 implant-specific scispacy 1
약물 2019 scispacy 1
약물 [BACKGROUND] Textured implants were scispacy 1
약물 [RESULTS] A scispacy 1
질환 contracture C0009917
Contracture
scispacy 1
질환 malrotation C0221210
Congenital malrotation of intestine
scispacy 1
질환 malrotation of textured shaped implants scispacy 1
기타 Women scispacy 1
기타 Patients scispacy 1
기타 patient scispacy 1

MeSH Terms

Humans; Female; Prospective Studies; Breast Implants; Middle Aged; Adult; Breast Implantation; Prosthesis Design; Device Removal; Rotation; Prosthesis Failure; Aged; Reoperation; Patient Satisfaction