Long-Term Outcomes following Hybrid Breast Reconstruction.
Abstract
[BACKGROUND] Hybrid breast reconstruction combines free tissue transfer with implant placement. Various mesh products have been successfully used to secure the implant position in these reconstructions. In this study, the authors investigate the impact of mesh type on long-term outcomes following hybrid breast reconstruction.
[METHODS] A retrospective analysis of all patients with at least 24 months of follow-up after immediate bilateral prepectoral hybrid breast reconstruction was performed. Univariate and multivariable regression analyses were used to evaluate long-term outcomes and compare breasts reconstructed with polyglactin mesh versus acellular dermal matrix (ADM).
[RESULTS] Thirty-nine patients (78 breasts) who underwent hybrid breast reconstruction with an average follow-up period of 50.4 months (range, 27 to 73 months) were included in the study. Postoperative complications included hematoma ( n = 2 [2.6%]), mastectomy skin necrosis ( n = 12 [15.4%]), and fat necrosis ( n = 6 [7.7%]). There were no instances of implant infection, implant exposure, or flap failure. Polyglactin mesh and ADM were used in 24 breasts and 54 breasts, respectively. Implant malposition and capsular contracture occurred more frequently in the polyglactin cohort leading to 10 (41.7%) instances of reoperation for implant replacement compared with only 1 (1.9%) in the ADM cohort ( P < 0.001). On multivariable regression analysis, polyglactin mesh was associated with a 36-fold greater probability of requiring implant replacement compared with ADM ( P = 0.006).
[CONCLUSION] ADM (versus polyglactin mesh) is associated with lower rates of capsular contracture and implant malposition in the context of hybrid breast reconstruction.
[CLINICAL QUESTION/LEVEL OF EVIDENCE] Therapeutic, III.
[METHODS] A retrospective analysis of all patients with at least 24 months of follow-up after immediate bilateral prepectoral hybrid breast reconstruction was performed. Univariate and multivariable regression analyses were used to evaluate long-term outcomes and compare breasts reconstructed with polyglactin mesh versus acellular dermal matrix (ADM).
[RESULTS] Thirty-nine patients (78 breasts) who underwent hybrid breast reconstruction with an average follow-up period of 50.4 months (range, 27 to 73 months) were included in the study. Postoperative complications included hematoma ( n = 2 [2.6%]), mastectomy skin necrosis ( n = 12 [15.4%]), and fat necrosis ( n = 6 [7.7%]). There were no instances of implant infection, implant exposure, or flap failure. Polyglactin mesh and ADM were used in 24 breasts and 54 breasts, respectively. Implant malposition and capsular contracture occurred more frequently in the polyglactin cohort leading to 10 (41.7%) instances of reoperation for implant replacement compared with only 1 (1.9%) in the ADM cohort ( P < 0.001). On multivariable regression analysis, polyglactin mesh was associated with a 36-fold greater probability of requiring implant replacement compared with ADM ( P = 0.006).
[CONCLUSION] ADM (versus polyglactin mesh) is associated with lower rates of capsular contracture and implant malposition in the context of hybrid breast reconstruction.
[CLINICAL QUESTION/LEVEL OF EVIDENCE] Therapeutic, III.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 6 | |
| 재료 | adm
|
무세포진피기질 | dict | 5 | |
| 합병증 | capsular contracture
|
피막구축 | dict | 2 | |
| 시술 | flap
|
피판재건술 | dict | 1 | |
| 해부 | tissue
|
scispacy | 1 | ||
| 해부 | breasts
|
scispacy | 1 | ||
| 해부 | skin
|
scispacy | 1 | ||
| 해부 | fat
|
scispacy | 1 | ||
| 합병증 | hematoma
|
혈종 | dict | 1 | |
| 합병증 | infection
|
감염 | dict | 1 | |
| 합병증 | skin necrosis
|
괴사 | dict | 1 | |
| 합병증 | necrosis
|
괴사 | dict | 1 | |
| 재료 | acellular dermal matrix
|
무세포진피기질 | dict | 1 | |
| 약물 | [BACKGROUND] Hybrid breast
|
scispacy | 1 | ||
| 약물 | [RESULTS] Thirty-nine
|
scispacy | 1 | ||
| 질환 | prepectoral hybrid breast reconstruction
|
scispacy | 1 | ||
| 질환 | contracture
|
C0009917
Contracture
|
scispacy | 1 | |
| 질환 | implant malposition
|
C4552558
Implant malposition
|
scispacy | 1 | |
| 질환 | Hybrid Breast
|
scispacy | 1 | ||
| 질환 | breasts
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 | ||
| 기타 | bilateral prepectoral hybrid breast
|
scispacy | 1 |
MeSH Terms
Humans; Female; Retrospective Studies; Middle Aged; Adult; Surgical Mesh; Breast Neoplasms; Postoperative Complications; Mastectomy; Breast Implantation; Mammaplasty; Treatment Outcome; Acellular Dermis; Follow-Up Studies; Breast Implants; Reoperation; Aged
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Penetrating globe injury following periocular hyaluronic acid filler injection: A case report.
- From Palliation After Angiosarcoma Resection to Totally Autologous Aesthetic Breast Reconstruction Combining Kiss Latissimus Dorsi Flap and Contralateral Breast Sharing Internal Mammary Artery Perforator Flap: A Case Report.