Our Experience Using Round Nano-Surface Ergonomix Implants for Breast Reconstruction: A Single-Center Retrospective Study.

Aesthetic surgery journal 2023 Vol.43(2) p. NP102-NP111

Adelson D, Singolda R, Haran O, Madah E, Barsuk D, Barnea Y

관련 도메인

Abstract

[BACKGROUND] Round nano-surface Ergonomix (Motiva, Establishment Labs; Alajuela, Costa Rica) implants were developed to address concerns regarding capsular contracture and textured anatomical breasts implants.

[OBJECTIVES] The authors describe their early experience with Ergonomix implants in breast reconstruction.

[METHODS] The authors retrospectively reviewed the charts of 212 patients (321 breasts) who underwent breast reconstruction employing round nano-surface Ergonomix implants between June 2017 and December 2020. Patients were followed for at least 12 months postoperatively. Demographics, surgical data, and postoperative surgical outcomes were recorded. Postoperative physical well-being and satisfaction with the breasts and implant were evaluated with Breast-Q questionnaires.

[RESULTS] Of 211 patients, 75.4% had surgery due to cancer, and 24.6% underwent prophylactic surgery. Major complications occurred in 21 breasts (6.5%), of which 20 underwent revision operations. Reconstruction failed in 1 case (0.3%). Eleven breasts (3.4%) had minor complications. Immediate breast reconstruction, irradiated breasts, and smokers had higher rates of complications (P = 0.009, 0.02, 0.022, respectively). Rippling was more common in the pre-pectoral implant plane compared with sub-pectoral reconstruction (9% vs 1.2%, P = 0.001). Capsular contracture rate was 0.9% and occurred only in irradiated breasts. Implant malposition (inferiorly and laterally) occurred in 6.5% of the breasts, with no association between implant malposition and implant plane. Early follow-up demonstrated high patient satisfaction with the implant and breasts, and high scores in terms of patients' physical well-being.

[CONCLUSIONS] Breast reconstruction employing the round nano-surface Ergonomix implant yielded low complication rates and high patient satisfaction. The transition from macro-textured to nano-surface implants has operative implications requiring a learning curve and surgical adjustments.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 breast 유방 dict 6
합병증 capsular contracture 피막구축 dict 2
해부 breasts scispacy 1
해부 sub-pectoral scispacy 1
해부 nano-surface scispacy 1
합병증 breasts scispacy 1
약물 nano-surface scispacy 1
약물 breasts C0006141
Breast
scispacy 1
약물 [BACKGROUND] Round nano-surface scispacy 1
약물 [OBJECTIVES] scispacy 1
약물 [CONCLUSIONS] Breast scispacy 1
질환 contracture C0009917
Contracture
scispacy 1
질환 breasts C0006141
Breast
scispacy 1
질환 cancer C0006826
Malignant Neoplasms
scispacy 1
질환 implant malposition C4552558
Implant malposition
scispacy 1
기타 Labs scispacy 1
기타 capsular scispacy 1
기타 patients scispacy 1
기타 smokers scispacy 1
기타 patient scispacy 1

MeSH Terms

Humans; Female; Retrospective Studies; Mammaplasty; Breast Implants; Breast; Breast Implantation; Contracture; Breast Neoplasms

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문