Our Experience Using Round Nano-Surface Ergonomix Implants for Breast Reconstruction: A Single-Center Retrospective Study.
Abstract
[BACKGROUND] Round nano-surface Ergonomix (Motiva, Establishment Labs; Alajuela, Costa Rica) implants were developed to address concerns regarding capsular contracture and textured anatomical breasts implants.
[OBJECTIVES] The authors describe their early experience with Ergonomix implants in breast reconstruction.
[METHODS] The authors retrospectively reviewed the charts of 212 patients (321 breasts) who underwent breast reconstruction employing round nano-surface Ergonomix implants between June 2017 and December 2020. Patients were followed for at least 12 months postoperatively. Demographics, surgical data, and postoperative surgical outcomes were recorded. Postoperative physical well-being and satisfaction with the breasts and implant were evaluated with Breast-Q questionnaires.
[RESULTS] Of 211 patients, 75.4% had surgery due to cancer, and 24.6% underwent prophylactic surgery. Major complications occurred in 21 breasts (6.5%), of which 20 underwent revision operations. Reconstruction failed in 1 case (0.3%). Eleven breasts (3.4%) had minor complications. Immediate breast reconstruction, irradiated breasts, and smokers had higher rates of complications (P = 0.009, 0.02, 0.022, respectively). Rippling was more common in the pre-pectoral implant plane compared with sub-pectoral reconstruction (9% vs 1.2%, P = 0.001). Capsular contracture rate was 0.9% and occurred only in irradiated breasts. Implant malposition (inferiorly and laterally) occurred in 6.5% of the breasts, with no association between implant malposition and implant plane. Early follow-up demonstrated high patient satisfaction with the implant and breasts, and high scores in terms of patients' physical well-being.
[CONCLUSIONS] Breast reconstruction employing the round nano-surface Ergonomix implant yielded low complication rates and high patient satisfaction. The transition from macro-textured to nano-surface implants has operative implications requiring a learning curve and surgical adjustments.
[OBJECTIVES] The authors describe their early experience with Ergonomix implants in breast reconstruction.
[METHODS] The authors retrospectively reviewed the charts of 212 patients (321 breasts) who underwent breast reconstruction employing round nano-surface Ergonomix implants between June 2017 and December 2020. Patients were followed for at least 12 months postoperatively. Demographics, surgical data, and postoperative surgical outcomes were recorded. Postoperative physical well-being and satisfaction with the breasts and implant were evaluated with Breast-Q questionnaires.
[RESULTS] Of 211 patients, 75.4% had surgery due to cancer, and 24.6% underwent prophylactic surgery. Major complications occurred in 21 breasts (6.5%), of which 20 underwent revision operations. Reconstruction failed in 1 case (0.3%). Eleven breasts (3.4%) had minor complications. Immediate breast reconstruction, irradiated breasts, and smokers had higher rates of complications (P = 0.009, 0.02, 0.022, respectively). Rippling was more common in the pre-pectoral implant plane compared with sub-pectoral reconstruction (9% vs 1.2%, P = 0.001). Capsular contracture rate was 0.9% and occurred only in irradiated breasts. Implant malposition (inferiorly and laterally) occurred in 6.5% of the breasts, with no association between implant malposition and implant plane. Early follow-up demonstrated high patient satisfaction with the implant and breasts, and high scores in terms of patients' physical well-being.
[CONCLUSIONS] Breast reconstruction employing the round nano-surface Ergonomix implant yielded low complication rates and high patient satisfaction. The transition from macro-textured to nano-surface implants has operative implications requiring a learning curve and surgical adjustments.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 해부 | breast
|
유방 | dict | 6 | |
| 합병증 | capsular contracture
|
피막구축 | dict | 2 | |
| 해부 | breasts
|
scispacy | 1 | ||
| 해부 | sub-pectoral
|
scispacy | 1 | ||
| 해부 | nano-surface
|
scispacy | 1 | ||
| 합병증 | breasts
|
scispacy | 1 | ||
| 약물 | nano-surface
|
scispacy | 1 | ||
| 약물 | breasts
|
C0006141
Breast
|
scispacy | 1 | |
| 약물 | [BACKGROUND] Round nano-surface
|
scispacy | 1 | ||
| 약물 | [OBJECTIVES]
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS] Breast
|
scispacy | 1 | ||
| 질환 | contracture
|
C0009917
Contracture
|
scispacy | 1 | |
| 질환 | breasts
|
C0006141
Breast
|
scispacy | 1 | |
| 질환 | cancer
|
C0006826
Malignant Neoplasms
|
scispacy | 1 | |
| 질환 | implant malposition
|
C4552558
Implant malposition
|
scispacy | 1 | |
| 기타 | Labs
|
scispacy | 1 | ||
| 기타 | capsular
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 | ||
| 기타 | smokers
|
scispacy | 1 | ||
| 기타 | patient
|
scispacy | 1 |
MeSH Terms
Humans; Female; Retrospective Studies; Mammaplasty; Breast Implants; Breast; Breast Implantation; Contracture; Breast Neoplasms
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- The Plastic Surgery In-Service Examination: A Scoping Review.
- Clinical outcomes of synthetic absorbable mesh use in breast surgery: First case series in reconstruction and aesthetic mastopexy.