Poly Implant Prothèse silicone breast implants: implant dynamics and capsular contracture.

European journal of plastic surgery 2018 Vol.41(5) p. 563-570

Bachour Y, Heinze ZCM, Dormaar TS, van Selms WG, Ritt MJPF, Niessen FB

관련 도메인

Abstract

[BACKGROUND] The Poly Implant Prothèse (PIP) implants were withdrawn from the market in 2010 due to the use of low-grade silicone, causing a high risk for implant rupture. The aim of this study was to investigate the implant dynamics of PIP breast implants, as well as to determine the rate and predictors of implant gel bleeding, rupture, and capsular contracture in PIP implants.

[METHODS] Eighty women with a total of 152 PIP implants who underwent a reoperation in 2012 were enrolled in this study. Physical investigation included assessing the Baker score and demographics were retrospectively traced in medical records. The pre- and post-operative volumes of the implants were calculated and their state was determined intraoperatively by the surgeon.

[RESULTS] The implants were removed after a mean implant duration of 11 ± 2.1 years. Gel bleed and implant rupture occurred in respectively 42 and 25% of the implants. Intact implants had post-operative volume increase as well as decrease. There was a correlation between gel bleeding and more post-operative implant volume increase ( ≤ 0.05). Capsular contracture had a protective effect against post-operative implant volume increase ( ≤ 0.05), while a post-operative implant volume increase provided a protective influence in developing capsular contracture ( ≤ 0.05). Additionally, implant rupture led to a higher risk of capsular contracture ( ≤ 0.05).

[CONCLUSIONS] We managed to illustrate that PIP implant shells were too permeable and that there is a correlation between gel bleeding and the increase of the post-operative implant volume. Implant rupture led to a higher risk for developing capsular contracture.Level of evidence: Level III, risk / prognostic study.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
합병증 capsular contracture 피막구축 dict 6
합병증 implant rupture 보형물 파열 dict 4
해부 breast 유방 dict 2
약물 Poly Implant Prothèse scispacy 1
약물 [BACKGROUND] scispacy 1
약물 PIP → Poly Implant Prothèse scispacy 1
약물 [CONCLUSIONS] scispacy 1
질환 silicone breast scispacy 1
질환 bleeding C0019080
Hemorrhage
scispacy 1
질환 rupture C3203359
Rupture
scispacy 1
질환 bleed C0019080
Hemorrhage
scispacy 1
질환 volume increase scispacy 1
질환 low-grade scispacy 1
기타 PIP → Poly Implant Prothèse scispacy 1
기타 women scispacy 1
기타 capsular scispacy 1

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문