Back to the future: a 15-year experience with polyurethane foam-covered breast implants using the partial-subfascial technique.
Abstract
[BACKGROUND] Implants with a polyurethane foam cover have been used by plastic surgeons since Ashley described them in 1970. Overwhelming evidence confirms the benefits of these implants, especially the extremely low incidence of capsular contracture (grades 3 and 4, Baker classification). On the other hand, except for a transient and self-limited rash, there is no evidence that polyurethane implants present more complications than texturized or smooth gel implants. Due to concerns of polyurethane-induced cancer, these implants were withdrawn in United States after approximately 110,000 American women had received them. This fact, together with the probability that these implants will be reintroduced in the United States, suggests that continued monitoring of their long-term safety and effectiveness is mandatory.
[METHODS] A retrospective study analyzed the outcomes of 996 implants inserted during a period of 15 years. The incidence of early and late complications was analyzed as well as the aesthetic outcome.
[RESULTS] The complications evaluated included hematoma (0.6%), infection (0.4%), seroma (0.8%), rash (4.3%), wound dehiscence (0%), capsular contracture (0.4%), implant malposition (0.8%), need for revisional surgery (1.2%), implant rupture (0.7%), rippling (1.8%), and polyurethane-related cancer (0%). Regarding the aesthetic outcome, 95% of the patients expressed satisfaction with their final result.
[CONCLUSION] The polyurethane foam-covered implants have been proven safe for use in breast surgery. They provide the lowest rate of capsular contracture (0.4% in the current study) and excellent aesthetic results.
[METHODS] A retrospective study analyzed the outcomes of 996 implants inserted during a period of 15 years. The incidence of early and late complications was analyzed as well as the aesthetic outcome.
[RESULTS] The complications evaluated included hematoma (0.6%), infection (0.4%), seroma (0.8%), rash (4.3%), wound dehiscence (0%), capsular contracture (0.4%), implant malposition (0.8%), need for revisional surgery (1.2%), implant rupture (0.7%), rippling (1.8%), and polyurethane-related cancer (0%). Regarding the aesthetic outcome, 95% of the patients expressed satisfaction with their final result.
[CONCLUSION] The polyurethane foam-covered implants have been proven safe for use in breast surgery. They provide the lowest rate of capsular contracture (0.4% in the current study) and excellent aesthetic results.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 합병증 | capsular contracture
|
피막구축 | dict | 3 | |
| 해부 | breast
|
유방 | dict | 2 | |
| 해부 | smooth
|
scispacy | 1 | ||
| 합병증 | implant rupture
|
보형물 파열 | dict | 1 | |
| 합병증 | wound
|
scispacy | 1 | ||
| 합병증 | hematoma
|
혈종 | dict | 1 | |
| 합병증 | seroma
|
장액종 | dict | 1 | |
| 합병증 | infection
|
감염 | dict | 1 | |
| 합병증 | wound dehiscence
|
상처열개 | dict | 1 | |
| 약물 | polyurethane
|
C0032616
Polyurethanes
|
scispacy | 1 | |
| 약물 | [BACKGROUND] Implants
|
scispacy | 1 | ||
| 기법 | subfascial
|
근막하 평면 | dict | 1 | |
| 질환 | rash
|
C0015230
Exanthema
|
scispacy | 1 | |
| 질환 | cancer
|
C0006826
Malignant Neoplasms
|
scispacy | 1 | |
| 질환 | implant malposition
|
C4552558
Implant malposition
|
scispacy | 1 | |
| 기타 | women
|
scispacy | 1 | ||
| 기타 | patients
|
scispacy | 1 |
MeSH Terms
Adult; Breast Implantation; Breast Implants; Female; Humans; Implant Capsular Contracture; Polyurethanes; Prosthesis Design; Retrospective Studies; Young Adult
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- The impact of three-dimensional simulation and virtual reality technologies on surgical decision-making and postoperative satisfaction in aesthetic surgery: a preliminary study.
- Cutaneous fistula of the breast: A complication of cosmetic autologous fat transfer.
- Epidermal inclusion cyst after breast reduction mammoplasty.
- Penetrating globe injury following periocular hyaluronic acid filler injection: A case report.
- The Plastic Surgery In-Service Examination: A Scoping Review.