[A scanning electron microscopy study of the surface of porous-textured breast implants and their capsules. Description of the "velcro" effect of porous-textured breast prostheses].

Annales de chirurgie plastique et esthetique 2001 Vol.46(1) p. 23-30

Danino A, Rocher F, Blanchet-Bardon C, Revol M, Servant JM

관련 도메인

Abstract

The efficacy of breast prosthesis texturing in the prevention of capsular contracture has been established for about 20 years. This successful procedure has led to the development and marketing of a number of different models. In the present study, four porous-textured breast prostheses have been examined: the Arion monoblock implant, the CUI (McGahn), the Biocell (Mcgahn), and the Sebbin LS21. Scanning electron microscopic (SEM) investigation of the implant surfaces of the different prostheses was carried out on new samples received from the manufacturers. During a prospective study on eight patients, capsule samples corresponding to the four above-mentioned prostheses were taken to determine whether a secondary intervention was necessary for correction of asymmetry or malpositioning. These samples were analyzed by SEM to investigate whether there could be a correlation between prosthesis texturing and the aspect of the corresponding capsules. Significant ultrastructural differences were found between the various prostheses examined: the results showed that only the CUI and Biocell prostheses presented a mirror image of the capsule texturing, with a correspondence between the depressions on the prosthesis and the contacts on the capsule. This finding seems to be linked to the existence of a critical size for the pores that constitute the implant surface. This observation led to the hypothesis of an adhesive "velcro" effect between the prosthesis and its capsule. Although the latter may not be directly linked to the prevention of capsular contracture it can, however, have a major effect on implant stabilization in cases of primary breast reconstruction and in possible secondary adjustments of asymmetry and malpositioning.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
해부 breast 유방 dict 5
합병증 capsular contracture 피막구축 dict 2
합병증 asymmetry 비대칭 dict 2
해부 surface scispacy 1
해부 pores scispacy 1
약물 electron scispacy 1
질환 porous-textured breast prostheses scispacy 1
질환 depressions C0011570
Mental Depression
scispacy 1
질환 capsule scispacy 1
기타 patients scispacy 1

MeSH Terms

Adult; Breast Implants; Equipment Failure Analysis; Female; Humans; Microscopy, Electron, Scanning; Middle Aged; Porosity; Prospective Studies; Prosthesis Design; Prosthesis Failure; Reoperation; Surface Properties

🔗 함께 등장하는 도메인

이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들

관련 논문