Polyurethane foam-covered implants and capsular contracture: a laboratory investigation.

Plastic and reconstructive surgery 1990 Vol.86(4) p. 708-10; discussion 711-4

Caffee HH, Hathaway C

관련 도메인

Abstract

Experiments were conducted in rabbits comparing polyurethane foam-covered implants with otherwise identical smooth silicone gel implants. Using five objective methods of measurement of capsular contracture, no significant difference could be identified. The foam-covered implants consistently developed capsular contracture, although in most cases this was of mild degree and would not have been clinically significant. In the two foam-covered implants with hard contractures, there was no evidence of hematoma or separation of the foam.

추출된 의학 개체 (NER)

유형영어 표현한국어 / 풀이UMLS CUI출처등장
합병증 capsular contracture 피막구축 dict 3
해부 smooth scispacy 1
합병증 hematoma 혈종 dict 1
약물 silicone C0037114
silicones
scispacy 1
기타 rabbits scispacy 1
기타 capsular scispacy 1

MeSH Terms

Animals; Breast; Contracture; Female; Gels; Polyurethanes; Prospective Studies; Prostheses and Implants; Prosthesis Design; Rabbits; Silicones