Automated Ptosis Measurements From Facial Photographs.
Abstract
[IMPORTANCE] Measurements of the margin reflex distances 1 and 2 are crucial for the surgical planning of ptosis repair and blepharoplasty. Facial photographs annotated with automated measurements of eyelid position could provide objective, accurate, and reproducible documentation of these features.
[OBJECTIVES] To describe a software algorithm for determining the margin reflex distances 1 and 2 from facial photographs and to evaluate its agreement with manual measurements of the margin reflex distances 1 and 2.
[DESIGN, SETTING, AND PARTICIPANTS] Observational study at a single-surgeon oculoplastic private practice among 55 eyes of 28 adult volunteers. The study dates were July 30, 2014, to September 12, 2014. The dates of our analysis were October 12, 2014, to June 18, 2015.
[MAIN OUTCOMES AND MEASURES] Agreement between manual and automated measurements of the margin reflex distances 1 and 2.
[RESULTS] Among 55 eyes of 28 participants, automated margin reflex distance 1 measurements were strongly correlated with manual measurements (r = 0.97; 95% CI, r = 0.95 to r = 0.98; P < .001). The bias of automated margin reflex distance 1 measurements was 0.03 mm (95% CI, -0.06 to 0.12 mm), with 95% confidence limits of -0.66 and 0.71 mm. Automated margin reflex distance 2 measurements were strongly correlated with manual measurements (r = 0.96; 95% CI, r = 0.93 to r = 0.98; P < .001). The bias of automated margin reflex distance 2 measurements was 0.13 mm (95% CI, 0.03-0.22 mm), with 95% confidence limits of -0.54 and 0.80 mm.
[CONCLUSIONS AND RELEVANCE] Automated ptosis measurements produced by our software algorithm compare favorably with manually performed clinical measurements. An automated, photography-based system could provide an archival and highly reproducible means for obtaining the margin reflex distances 1 and 2 and other facial morphometric data.
[OBJECTIVES] To describe a software algorithm for determining the margin reflex distances 1 and 2 from facial photographs and to evaluate its agreement with manual measurements of the margin reflex distances 1 and 2.
[DESIGN, SETTING, AND PARTICIPANTS] Observational study at a single-surgeon oculoplastic private practice among 55 eyes of 28 adult volunteers. The study dates were July 30, 2014, to September 12, 2014. The dates of our analysis were October 12, 2014, to June 18, 2015.
[MAIN OUTCOMES AND MEASURES] Agreement between manual and automated measurements of the margin reflex distances 1 and 2.
[RESULTS] Among 55 eyes of 28 participants, automated margin reflex distance 1 measurements were strongly correlated with manual measurements (r = 0.97; 95% CI, r = 0.95 to r = 0.98; P < .001). The bias of automated margin reflex distance 1 measurements was 0.03 mm (95% CI, -0.06 to 0.12 mm), with 95% confidence limits of -0.66 and 0.71 mm. Automated margin reflex distance 2 measurements were strongly correlated with manual measurements (r = 0.96; 95% CI, r = 0.93 to r = 0.98; P < .001). The bias of automated margin reflex distance 2 measurements was 0.13 mm (95% CI, 0.03-0.22 mm), with 95% confidence limits of -0.54 and 0.80 mm.
[CONCLUSIONS AND RELEVANCE] Automated ptosis measurements produced by our software algorithm compare favorably with manually performed clinical measurements. An automated, photography-based system could provide an archival and highly reproducible means for obtaining the margin reflex distances 1 and 2 and other facial morphometric data.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | blepharoplasty
|
안검성형술 | dict | 1 | |
| 해부 | eyelid
|
눈꺼풀 | dict | 1 | |
| 해부 | eyes
|
scispacy | 1 | ||
| 약물 | [IMPORTANCE]
|
scispacy | 1 | ||
| 약물 | [OBJECTIVES]
|
scispacy | 1 | ||
| 약물 | [DESIGN
|
scispacy | 1 | ||
| 약물 | [MAIN OUTCOMES AND
|
scispacy | 1 | ||
| 약물 | [CONCLUSIONS AND
|
scispacy | 1 | ||
| 질환 | ptosis repair
|
C0197280
Repair of blepharoptosis
|
scispacy | 1 |
MeSH Terms
Adult; Aged; Aged, 80 and over; Algorithms; Blepharoptosis; Blinking; Diagnostic Techniques, Ophthalmological; Face; Female; Humans; Male; Middle Aged; Photography; Reproducibility of Results; Software; Young Adult
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Penetrating globe injury following periocular hyaluronic acid filler injection: A case report.
- Implications of Dermatologic Disorders in Facial Cosmetic Surgery: A Systematic Review.
- Mohs Surgery Defect Closure Using Blepharoplasty.
- Application of the SCIA-Pure Skin Perforator Flap in Bilateral Upper Eyelid Reconstruction: A Case Report and Review of the Literature.
- Combined minimally invasive lymphatic microsurgery and aligned nanofibrillar collagen scaffold for refractory post-traumatic eyelid lymphedema: A case report.