Short-Term Effects of Poly-L-Lactic Acid-b-Polyethylene Glycol Microsphere Injection on Different Adipose Tissue Types in Rats.
Abstract
[BACKGROUND] Wrinkles and sagging, characteristics of aging, are associated with reductions in collagen and fat. Poly-L-lactic acid (PLLA) is widely used clinically as a tissue filler owing to its good biocompatibility and ability to improve wrinkles and signs of aging. Despite extensive studies of the mechanism of action of PLLA when used as a dermal filler, few studies have examined its effects on adipose tissue.
[OBJECTIVES] The short-term effects of PLLA-b-polyethylene glycol (PEG) microspheres implanted in subcutaneous back adipose tissue (BAT) and visceral epididymal adipose tissue (EAT) of rats were examined.
[METHODS] The authors divided 15 male Sprague-Dawley rats into 5 groups based on implantation time, and PLLA-b-PEG microspheres were implanted into the BAT (3 groups were sampled at 6, 8, and 12 weeks) and EAT (2 groups were sampled at 6 and 12 weeks) of rats. Tissue samples were collected at different time points postimplantation and subjected to histological analyses using hematoxylin and eosin, Masson's trichrome, and immunofluorescence staining.
[RESULTS] Implantation of PLLA-b-PEG microspheres into different adipose tissues resulted in a mild and persistent inflammatory reaction, increased fibrous connective tissue, and noticeable collagen regeneration. Immunofluorescence showed the upregulation of uncoupling protein (UCP) 1 and UCP2 in the visceral adipose tissue surrounding the implant.
[CONCLUSIONS] PLLA-b-PEG microspheres exhibited good tissue compatibility and induced an increase in fibrous connective tissue postimplantation, potentially mitigating oxidative damage and improving adipose tissue quality.
[OBJECTIVES] The short-term effects of PLLA-b-polyethylene glycol (PEG) microspheres implanted in subcutaneous back adipose tissue (BAT) and visceral epididymal adipose tissue (EAT) of rats were examined.
[METHODS] The authors divided 15 male Sprague-Dawley rats into 5 groups based on implantation time, and PLLA-b-PEG microspheres were implanted into the BAT (3 groups were sampled at 6, 8, and 12 weeks) and EAT (2 groups were sampled at 6 and 12 weeks) of rats. Tissue samples were collected at different time points postimplantation and subjected to histological analyses using hematoxylin and eosin, Masson's trichrome, and immunofluorescence staining.
[RESULTS] Implantation of PLLA-b-PEG microspheres into different adipose tissues resulted in a mild and persistent inflammatory reaction, increased fibrous connective tissue, and noticeable collagen regeneration. Immunofluorescence showed the upregulation of uncoupling protein (UCP) 1 and UCP2 in the visceral adipose tissue surrounding the implant.
[CONCLUSIONS] PLLA-b-PEG microspheres exhibited good tissue compatibility and induced an increase in fibrous connective tissue postimplantation, potentially mitigating oxidative damage and improving adipose tissue quality.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 재료 | plla
|
폴리락트산 | dict | 6 | |
| 재료 | poly-l-lactic acid
|
폴리락트산 | dict | 2 | |
| 시술 | filler
|
필러 주입술 | dict | 1 | |
| 시술 | dermal filler
|
필러 주입술 | dict | 1 | |
| 해부 | subcutaneous
|
피하조직 | dict | 1 |
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Penetrating globe injury following periocular hyaluronic acid filler injection: A case report.
- Choroidal ischemia after self-injection of hyaluronic acid filler.
- Intra-articular therapies for synovial joint dysfunction: a comprehensive integrative review.
- Clinical safety of a low-modification hyaluronic acid filler (MoD 2%) for facial rejuvenation.
- Implant-based versus autologous mastopexy after massive weight loss: Complications and patient satisfaction.