Comparative Analysis of Hyaluronidase-Mediated Degradation Among Seven Hyaluronic Acid Fillers in Hairless Mice.
Abstract
[PURPOSE] Hyaluronic acid (HA) is the most common injectable dermal filler used for soft-tissue augmentation, and can be removed non-surgically by directly injecting hyaluronidase. In this study, the hyaluronidase-mediated degradation of different types of HA fillers implanted subcutaneously at the back of hairless mice having filler residence time of four days or three months were compared.
[METHODS] Two sites at the back of female hairless mice were subcutaneously implanted with 0.1-mL of one of the seven HA fillers (NLL, NL, NDL, NVL, and ND, JUV, and RES) and injected with 30 IU or 60 IU hyaluronidase per 0.1-mL filler after reaching a filler residence time of 4 or 91 days, respectively. Filler bolus projection was measured using three-dimensional optical imaging over a 72 h period, and the implantation sites were histologically examined 2 weeks after hyaluronidase injection.
[RESULTS] Following hyaluronidase injection, all seven HA fillers showed a rapid decrease of filler volume within 24 h, and complete degradation was confirmed by histological examination after 2 weeks. There was no significant difference in filler volume reduction rate among the seven HA fillers, and no evidence of macroscopic or microscopic adverse effects were observed at the implantation sites.
[CONCLUSION] All seven HA fillers show comparable susceptibility to hyaluronidase-mediated degradation. HA fillers with prolonged filler residence time may require a higher dose of hyaluronidase to achieve efficient degradation owing to tissue integration.
[METHODS] Two sites at the back of female hairless mice were subcutaneously implanted with 0.1-mL of one of the seven HA fillers (NLL, NL, NDL, NVL, and ND, JUV, and RES) and injected with 30 IU or 60 IU hyaluronidase per 0.1-mL filler after reaching a filler residence time of 4 or 91 days, respectively. Filler bolus projection was measured using three-dimensional optical imaging over a 72 h period, and the implantation sites were histologically examined 2 weeks after hyaluronidase injection.
[RESULTS] Following hyaluronidase injection, all seven HA fillers showed a rapid decrease of filler volume within 24 h, and complete degradation was confirmed by histological examination after 2 weeks. There was no significant difference in filler volume reduction rate among the seven HA fillers, and no evidence of macroscopic or microscopic adverse effects were observed at the implantation sites.
[CONCLUSION] All seven HA fillers show comparable susceptibility to hyaluronidase-mediated degradation. HA fillers with prolonged filler residence time may require a higher dose of hyaluronidase to achieve efficient degradation owing to tissue integration.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | filler
|
필러 주입술 | dict | 7 | |
| 재료 | ha
|
히알루론산 | dict | 7 | |
| 재료 | hyaluronic acid
|
히알루론산 | dict | 2 | |
| 시술 | dermal filler
|
필러 주입술 | dict | 1 |
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
관련 논문
- Penetrating globe injury following periocular hyaluronic acid filler injection: A case report.
- Choroidal ischemia after self-injection of hyaluronic acid filler.
- Intra-articular therapies for synovial joint dysfunction: a comprehensive integrative review.
- Clinical safety of a low-modification hyaluronic acid filler (MoD 2%) for facial rejuvenation.
- A Fibrous-Porous Microsphere-Based Composite Filler for Synchronized Immediate and Long-Term Soft Tissue Restoration.