Enhancing lipoaspirate efficiency by altering liposuction cannula design.
[BACKGROUND] Interplay between the components of a lipoplasty system (suction pump, suction tubing, collection canister, and cannula) determines liposuction efficiency.
- 연구 설계 cross-sectional
APA
Beck DO, Davis K, Rohrich RJ (2014). Enhancing lipoaspirate efficiency by altering liposuction cannula design.. Plastic and reconstructive surgery. Global open, 2(10), e222. https://doi.org/10.1097/GOX.0000000000000101
MLA
Beck DO, et al.. "Enhancing lipoaspirate efficiency by altering liposuction cannula design.." Plastic and reconstructive surgery. Global open, vol. 2, no. 10, 2014, pp. e222.
PMID
25426339
Abstract
[BACKGROUND] Interplay between the components of a lipoplasty system (suction pump, suction tubing, collection canister, and cannula) determines liposuction efficiency. However, in clinical practice, none of the components are more important than the cannula. Cannula design including port design, port placement, and shaft characteristics is the single most influential contributor to flow resistance and dramatically effects speed of aspiration and final contour. Many variations on port design and placement are available, yet functional enhancements to the cannula shaft have largely been ignored. We have engineered a set of novel cannulas addressing vital elements of cannula design in the effort to enhance aspiration efficiency and efficacy.
[METHODS] Two novel cannula designs (dual- and multiport, in-line configuration), created using a unique proprietary manufacturing process, were evaluated against a popular industry standard design (tri-port, Mercedes configuration) to assess aspiration efficiency. Cannulas with shaft diameters of 3, 4, and 5 mm were attached to a standardized lipoplasty system and evaluated in real time for their ability to aspirate a viscous applesauce medium over a 5-minute time course. For each cannula, we calculated (1) the cross-sectional area of the cannula shaft, (2) single and total port area, (3) port-to-shaft ratio, and (4) theoretical resistance.
[RESULTS] The relationship between the cannula shaft and cannula port(s) directly influenced flow dynamics. Comparing medium uptake time, aspiration efficiency and the aspiration curves demonstrated a significant improvement of the 2 novel cannulas over the standard cannula in the 5- and 4-mm designations. In the 3-mm group, a difference in uptake time remained. However, a significant difference in aspiration efficiency was only seen between the dual-port novel cannula and tri-port Mercedes standard cannula. Further, differences in the aspiration curves between all 3-mm cannulas approached but did not reach significance.
[CONCLUSIONS] We have developed 2 novel cannulas that maximize port features and seek to minimize the internal shaft resistance. Both designs demonstrate enhanced aspiration and uptake compared with an industry standard design.
[METHODS] Two novel cannula designs (dual- and multiport, in-line configuration), created using a unique proprietary manufacturing process, were evaluated against a popular industry standard design (tri-port, Mercedes configuration) to assess aspiration efficiency. Cannulas with shaft diameters of 3, 4, and 5 mm were attached to a standardized lipoplasty system and evaluated in real time for their ability to aspirate a viscous applesauce medium over a 5-minute time course. For each cannula, we calculated (1) the cross-sectional area of the cannula shaft, (2) single and total port area, (3) port-to-shaft ratio, and (4) theoretical resistance.
[RESULTS] The relationship between the cannula shaft and cannula port(s) directly influenced flow dynamics. Comparing medium uptake time, aspiration efficiency and the aspiration curves demonstrated a significant improvement of the 2 novel cannulas over the standard cannula in the 5- and 4-mm designations. In the 3-mm group, a difference in uptake time remained. However, a significant difference in aspiration efficiency was only seen between the dual-port novel cannula and tri-port Mercedes standard cannula. Further, differences in the aspiration curves between all 3-mm cannulas approached but did not reach significance.
[CONCLUSIONS] We have developed 2 novel cannulas that maximize port features and seek to minimize the internal shaft resistance. Both designs demonstrate enhanced aspiration and uptake compared with an industry standard design.
추출된 의학 개체 (NER)
| 유형 | 영어 표현 | 한국어 / 풀이 | UMLS CUI | 출처 | 등장 |
|---|---|---|---|---|---|
| 시술 | liposuction
|
지방흡입 | dict | 2 | |
| 시술 | lipoplasty
|
지방흡입 | dict | 2 | |
| 해부 | shaft
|
scispacy | 1 | ||
| 합병증 | shaft
|
scispacy | 1 | ||
| 기타 | cannulas
|
scispacy | 1 |
🔗 함께 등장하는 도메인
이 논문이 속한 카테고리와 같은 논문에서 자주 함께 다뤄지는 카테고리들
같은 제1저자의 인용 많은 논문 (1)
관련 논문
- Quantitative Assessment of Cannula Kinematics in Liposuction Surgical Procedures Using a Marker-Based Tracking System.
- Fat harvesting protocol for enhanced stem cell viability - pilot study.
- Scarless Infragluteal Fixation (SIF): Correction of Post-Liposuction Infragluteal Deformity.
- [Super microsurgical lymphaticovenular anastomosis for limb lymphedema: An outcome analysis based on clinical stage and indocyanine green pattern].
- Iatrogenic pneumothorax associated with surgeries at anatomically thoracic-adjacent and non-adjacent sites: case report and scoping review.